首页产品车载电缆

RSE/STD/024 Part 6 Rolling Stock Cable

Voltage Cable Type Construction Number of Cores Cross Sectional
Areas/Stranding Class
Design Standard Fire Standard
300/500V Single Core, unsheathed CU/EM 104 EVA 1C 0.5mm2-4mm2, 19/37 stranding RSE/STD/024 Part 6

IEC 332-3C

IEC 754 IEC1034

300/500V Single Core, unsheathed CU/EM 104 EVA 1C 0.5mm2-10mm2, Class 5 stranding RSE/STD/024 Part 6

IEC 332-3C

IEC 754 IEC1034

300/500V Single Core, unsheathed CU/EM 104 EVA 1C 1.0mm2-6.0mm2, Class 5 stranding RSE/STD/024 Part 6

IEC 332-3C

IEC 754 IEC1034

300/500V Multicore, with jacketType Ⅶ CU/EI 104 EPR/EM 104 EVA 12/42C 1.0mm2-1.5mm2, Class 5 stranding RSE/STD/024 Part 6

IEC 332-3C

IEC 754 IEC1034

300/500V Multicore, with jacket Type Ⅻ CU/EI 104 EPR/EM 104 EVA 12/42C 1.0mm2-1.5mm2, Class 5 stranding RSE/STD/024 Part 6

IEC 332-3C

IEC 754 IEC1034

300/500V Multipair, with jacket screened CU/EI 104 EPR/CUTO/EM 104 EVA 1,2,3 Prs 0.5mm2-1.0mm2, Class 5 stranding RSE/STD/024 Part 6

IEC 332-3C

IEC 754 IEC1034

300/500V Multipair, with jacket screened CU/EI 104 EPR/CUTO/EM 104 EVA 1,2,3,4 Prs 0.5mm2-1.0mm2, Class 5 stranding RSE/STD/024 Part 6

IEC 332-3C

IEC 754 IEC1034

600/1000V Single Core, unsheathed CU/EM 104 EVA 1C 0.5mm2-4mm2, 19/37 strand RSE/STD/024 Part 6

IEC 332-3C

IEC 754 IEC1034

600/1000V Single Core, unsheathed CU/EM 104 EVA 1C 0.75mm2-300mm2, Class 5 stranding RSE/STD/024 Part 6

IEC 332-3C

IEC 754 IEC1034

600/1000V Single Core, unsheathed CU/EM 104 EVA 1C 50mm2-185mm2, Class 5 stranding RSE/STD/024 Part 6

IEC 332-3C

IEC 754 IEC1034

600/1000V Multicore, with jacket CU/EI 104 EPR/EM 104 EVA 10/20C 2.5mm2-4mm2, Class 5 stranding RSE/STD/024 Part 6

IEC 332-3C

IEC 754 IEC1034

600/1000V Singlepair, with jacket screened CU/EI 104 EPR/CUTO/EM 104 EVA 1 Prs 1.0mm2, Class 5 stranding RSE/STD/024 Part 6

IEC 332-3C

IEC 754 IEC1034

300/500V Singlecore RSE/STD/024 Part 6 Rolling StockType Ⅳ Cable, unsheathed

Cross- sectional Area 0.5mm2-4mm2
Voltage rating 300/500V
Conductor Flexible Stranded Tinned Copper
Number of cores 1
Conductor class 19/37 AWG stranding
Insulation Cross linked EPR rubber type EI 107, Reduced Wall
Fire standard IEC 332-3C,IEC754;IEC1034-1/2

No. of Cores Cross Sectional Area (mm2) Number and Nominal Diameter of Strands (mm) Voltage Rating (V) Nominal Overall
Diameter
(mm)
Nominal Weight (kg/km)
singlecore 0.5 19/0.18 300/500 1.34 5.4
singlecore 0.75 37/0.16 300/500 1.56 8.0
singlecore 1.0 37/0.18 300/500 1.69 9.9
singlecore 1.5 37/0.23 300/500 2.07 15.7
singlecore 2.5 37/0.3 300/500 2.66 26.8
singlecore 4.0 37/0.37 300/500 3.32 41.1

300/500V Singlecore RSE/STD/024 Part 6 Rolling Stock Type Ⅴ Cable, unsheathed

Cross- sectional Area 0.5mm2-10mm2
Voltage rating 300/500V
Conductor Flexible Stranded Tinned Copper
Number of cores 1
Conductor class IEC 60228 Class 5
Insulation Cross linked EPR rubber type EI 107, Standard Wall
Fire standard IEC 332-3C,IEC754;IEC1034-1/2

No. of Cores Cross Sectional Area (mm2) Number and Nominal Diameter of Strands (mm) Voltage Rating (V) Nominal Overall
Diameter
(mm)
Nominal Weight (kg/km)
singlecore 0.5 16/0.2 300/500 2.32 9.6
singlecore 0.75 74/0.2 300/500 2.53 12.4
singlecore 1.0 32/0.2 300/500 2.71 15.1
singlecore 1.5 30/0.25 300/500 3.23 21.9
singlecore 2.5 50/0.25 300/500 3.7 33.5
singlecore 4.0 56/0.3 300/500 4.5 50.0
singlecore 6.0 84/0.3 300/500 5.09 74.6
singlecore 10.0 80/0.4 300/500 6.3 122.6

300/500V Single Core RSE/STD/024 Part 6 Rolling Stock Type Ⅺ screened Cable

Cross- sectional Area 1.0mm2-6.0mm2
Voltage rating 300/500V
Conductor Flexible Stranded Tinned Copper
Number of cores 1
Conductor class IEC 60228 Class 5
Insulation Cross linked EPR rubber type EI 107, Standard Wall
Fire standard IEC 332-3C,IEC754;IEC1034-1/2

No. of Cores Cross Sectional Area (mm2) Number and Nominal Diameter of Strands (mm) Voltage Rating (V) Nominal Overall
Diameter
(mm)
Nominal Weight (kg/km)
Singlecore 1.0 32/0.2 300/500 3.3 19.2
Singlecore 1.5 30/0.25 300/500 3.7 26.3
Singlecore 2.5 50/0.25 300/500 4.16 37.8
Singlecore 4.0 56/0.3 300/500 4.95 56.6
Singlecore 6.0 84/0.3 300/500 5.55 80.4

300/500V Multicore RSE/STD/024 Part 6 Rolling Stock Type Ⅶ Cable, with jacket

Cross- sectional Area 1.0mm2-1.5mm2
Voltage rating 300/500V
Conductor Flexible Stranded Tinned Copper
Number of cores 12-42
Conductor class IEC 60228 Class 5
Insulation Cross linked EPR rubber type EI 107, Standard Wall
Jacket Cross linked EVA rubber type EM 104
Fire standard IEC 332-3C,IEC754;IEC1034-1/2

No. of Cores Cross Sectional Area (mm2) Number and Nominal Diameter of Strands (mm) Voltage Rating (V) Nominal Overall
Diameter
(mm)
Nominal Weight (kg/km)
12 Core 1.0 32/0.2 30/50 20.25 309.0
42 Core 1.5 30/0.25 30/50 38.35 1661.0

300/500V Multicore RSE/STD/024 Part 6 Rolling Stock Type Ⅻ Cable, with jacket

Cross- sectional Area 1.0mm2-1.5mm2
Voltage rating 300/500V
Conductor Flexible Stranded Tinned Copper
Number of cores 12-42
Conductor class IEC 60228 Class 5
Insulation Cross linked EPR rubber type EI 107,Standard Wall
Jacket Cross linked EVA rubber type EMI 104
Fire standard IEC 332-3C,IEC754;IEC1034-1/2

No. of Cores Cross Sectional Area (mm2) Number and Nominal Diameter of Strands (mm) Voltage Rating (V) Nominal Overall
Diameter
(mm)
Nominal Weight (kg/km)
12 Core 1.0 32/0.2 300/500 20.3 309.0
42 Core 1.5 30/0.25 300/500 38.4 1661.0

123