British Standard Shipwiring cables to BS 6883

 

Flexible armoured screened Instrument cables

Flexible armoured screened Instrument cables

Manufactured in both pairs and triples these 150/250V instrumentation cables provide collective or individual screening through the use of metallic foils and drain wires. Offering good flexibility for installation in confined spaces or where difficult routing is necessary, the galvanised steel wire braid provides mechanical protection

Core Identification

Pairs :  Each pair black, white and numbered
Triples :   Each triple black, white, red and numbered
Alternative colour codes are available

Technical Information

Voltage rating 150/250V
Conductors Tinned, BS6360 class 2 or class 5
Temperature rating +90°C maximum conductor temperature
Static temperature rating -30°C to +90°C
Bending radius (static) 8 x cable O/D
Flame retardant IEC60332 part 3A, BS4066 part 3A

Technical Data

No. of
Pairs
Nominal Conductor
Cross-Sectional
Area mm²
Diameter over
inner sheath
min-max mm
Diameter over
outer sheath
min-max mm
 Pairs collective
 3  0.75  12.6 - 14.5  16.7 - 19.0
 7  0.75  16.6 - 18.7  20.9 - 23.8
 12  0.75  21.7 - 24.2  26.4 - 29.5
 20  0.75  27.3 - 30.1  33.3 - 37.1
 27  0.75  31.1 - 34.2  37.4 - 41.4
 37  0.75  34.4 - 37.7  41.0 - 45.0
 3  1  13.3 - 15.3  17.4 - 19.8
 7  1  17.6 - 19.8  22.1 - 25.1
 12  1  23.1 - 25.7  28.0 - 31.2
 20  1  29.1 - 31.9  35.3 - 39.2
 27  1  33.3 - 36.6  39.7 - 44.2
 37  1  36.9 - 40.3  43.7 - 48.3
 Pairs individual
 1  0.75  7.3 - 9.0  11.1 - 12.9
 3  0.75  12.6 - 14.5  16.7 - 19.0
 7  0.75  16.9 - 19.0  21.4 -24.3
 12  0.75  21.3 - 23.7  26.1 - 29.2
 20  0.75  27.0 - 29.8  33.2 - 37.0
 27  0.75  30.8 - 33.9  37.3 - 41.3
 37  0.75  25.9 - 39.3  42.9 - 47.5
 1  1  7.7 - 9.5  11.5 - 13.4
 3  1  13.5 - 15.5  17.6 - 20.0
 7  1  18.0 - 20.1  22.5 - 25.4
 12  1  22.8 - 25.4  28.6 - 31.8
 20  1  28.8 - 31.6  35.2 - 39.0
 27  1  32.8 - 36.0  39.5 - 44.0
 37  1  38.5 - 42.3  45.7 - 50.4
No. of
Triples
Nominal Conductor
Cross-Sectional
Area mm²
Diameter over
inner sheath
min-max mm
Diameter over
outer sheath
min-max mm
 Triples collective
 3   0.75   14.2 - 16.2   18.3 - 20.7 
 7   0.75   19.4 - 21.9   24.0 - 27.0 
 12   0.75   24.2 - 26.8   29.3 - 32.9 
 3   1   15.1 - 17.1   19.4 - 22.2 
 7   1   20.9 - 23.4   25.6 - 28.7 
 12   1   25.8 - 28.5   31.8 - 35.5 
 Triples individual
 1   0.75   7.7 - 9.4   11.5 - 13.3 
 3   0.75   14.2 - 16.2   18.6 - 20.9 
 7   0.75   19.7 - 22.1   24.4 - 27.4 
 12   0.75   24.4 - 27.1   30.4 - 34.1 
 1   1   8.4 - 10.1   12.1 - 14.0 
 3   1   15.0 - 17.2   19.4 - 22.3 
 7   1   21.0 - 23.5   25.7 - 28.8 
 12   1   26.2 - 28.9   32.2 - 36.0