PRODUCTS
- Aerial Bundled Cables
- Airport Cables
- Automotive Cables
- Alarm & Audio & Electronic Cables
- Belden Equivalent Cables
- Bus Cables
- Cable Glands
- Cables for Oil Industry
- Coaxial Cables
- Composite Cables
- Control Cables
- Data Cable
- Elevator Cables
- Fiber Optic Cables
- Fire Resisting Cable(Fireflix)
- Fire Retardant Cable(FIRETOX)
- Flame Retardant Cable (FIREGUARD)
- Flexible Cables
- Heat Detection Cables
- High Temperature Cables
- Highway Cables
- Industrial Cables
- Instrumentation Cables
- Lan Cables
- Marine Cable
- NEK606 Water Blocked Offshore & Marine Cables
- IEC60092 STANDARD Offshore & Marine Cables
- BS 6883&BS7917 STANDARD Offshore & Marine Cables
- UKOOA Offshore & Marine cables
- VG 95218 Navy Cables
- Mining Cables
- Airframe Wire
- Marine, OIL,GAS & Petrochemical Cables
- Power Cables
- Railway Cables
- Robotics
- Rolling Stock Cables
- Rubber & Crane Cables
- Security Cables
- Special Cables
- Spiral Cables
- Telephone Cables
- Thermocouple Cables
- BS 5308 Cable
- PAS 5308 Cable
- BS 5467 Cable
- BS 6724 Cable
- BS 6346 Cable
- BS 7211 Cable
- IEC 60502-1 Cable
HOT PRODUCTS
APPLICATIONS
|
Armoured VFD Cable with EMC Screening
Application
These cables are used for fixed installation in most areas and on open deck in ships. Design to meet requirements for Variable Frequency Drivers (VFD). Suitable for voltage peaks to 3kV (for cables ≥ 10mm2).
Construction
Conductor | Stranded copper conductor conforming to IEC60288 Class 5. |
Insulation | XLPE insulation conforming to IEC60092-351. |
Filler | Non-hygroscopic filler tape. |
Shield | Copper tape with a 100% coverage. |
Armor | Copper wire braid, coverage > 90%. |
Sheath | A black, polyolefine plastic, SHF1 conforming to IEC 60092-359. |
Technical Information
Rated voltage 1,8/3kV (3,6kV) |
Maximum conductor temperature + 90 °C |
Minimum recommended installation temperature -15 °C |
Lowest operation temperature -40 °C |
Flame-retardant IEC 60332-1-2 -test for single insulated wire and cable |
IEC 60332-3-22 -test for bunched wires and cables,category A |
Halogen-free IEC 60754 |
Smoke emission IEC 61034 |
Transfer impedance IEC 61196-1 (typical value 26dB over 1mΩ/m at 100MHz [20mΩ/m]) |
Cable Parameter
Number of conductors & cross-section | Cross- section of screen | Nominal outer diameter | Approx- imate weight | Current rating | Min. bending radius fixed installation |
---|---|---|---|---|---|
n x mm2 | mm3 | mm | kg/km | A | mm |
1x16 | 5,2 | 13,5 | 340 | 96 | 85 |
1x25 | 5,8 | 15,0 | 455 | 127 | 90 |
1x35 | 11,5 | 16,5 | 625 | 157 | 100 |
1x50 | 9,8 | 18,0 | 740 | 196 | 110 |
1x70 | 10,9 | 20,0 | 990 | 242 | 120 |
1x95 | 12,1 | 22,0 | 1275 | 293 | 135 |
1x120 | 13,2 | 23,5 | 1535 | 339 | 145 |
1x150 | 14,3 | 25,5 | 1830 | 389 | 155 |
1x185 | 15,4 | 27,5 | 2210 | 444 | 165 |
1x240 | 17,1 | 30,0 | 2830 | 522 | 180 |
1x300 | 18,6 | 33,0 | 3470 | 601 | 200 |
3x16 | 16,1 | 26,0 | 915 | 67 | 160 |
3x25 | 16,5 | 29,0 | 1215 | 89 | 175 |
3x35 | 18,2 | 31,5 | 1570 | 110 | 190 |
3x50 | 25,1 | 35,5 | 2040 | 137 | 215 |
3x70 | 35,0 | 39,0 | 2820 | 169 | 235 |
3x95 | 35,0 | 44,0 | 3645 | 205 | 265 |
3x120 | 38,1 | 48,0 | 4465 | 237 | 290 |
3x150 | 41,2 | 51,5 | 5335 | 272 | 310 |
3x95+3x16 | 35,0 | 44,0 | 4565 | 205 | 265 |
3x120+3x25 | 38,1 | 48,0 | 5190 | 237 | 290 |
3x150+3x25 | 41,2 | 51,5 | 6055 | 272 | 310 |