PRODUCTS
- Aerial Bundled Cables
- Airport Cables
- Automotive Cables
- Alarm & Audio & Electronic Cables
- Belden Equivalent Cables
- Bus Cables
- Cable Glands
- Cables for Oil Industry
- Coaxial Cables
- Composite Cables
- Control Cables
- Data Cable
- Elevator Cables
- Fiber Optic Cables
- Fire Resisting Cable(Fireflix)
- Fire Retardant Cable(FIRETOX)
- Flame Retardant Cable (FIREGUARD)
- Flexible Cables
- Heat Detection Cables
- High Temperature Cables
- Highway Cables
- Industrial Cables
- Instrumentation Cables
- Lan Cables
- Marine Cable
- NEK606 Water Blocked Offshore & Marine Cables
- IEC60092 STANDARD Offshore & Marine Cables
- BS 6883&BS7917 STANDARD Offshore & Marine Cables
- UKOOA Offshore & Marine cables
- VG 95218 Navy Cables
- Mining Cables
- Airframe Wire
- Marine, OIL,GAS & Petrochemical Cables
- Power Cables
- Railway Cables
- Robotics
- Rolling Stock Cables
- Rubber & Crane Cables
- Security Cables
- Special Cables
- Spiral Cables
- Telephone Cables
- Thermocouple Cables
- BS 5308 Cable
- PAS 5308 Cable
- BS 5467 Cable
- BS 6724 Cable
- BS 6346 Cable
- BS 7211 Cable
- IEC 60502-1 Cable
HOT PRODUCTS
APPLICATIONS
|
Shielded, High flexible PVC single conductor
Application
Applications as described above, additionally optimal compliance with electromagnetic compatibility (EMC) requirements on account of the approx. 85% coverage by the braided shielding.
Cable Construction
Bare copper, extra fine wire conductor to DIN VDE 0295 cl. 6 and IEC 60228 cl. 6;
PVC insulation, green-yellow;
PVC jacket compound TM2;
Jacket color gray;
Tinned copper braid, coverage approx. 85% .
Temperature range: flexing -5°C to +80°C; fixed installation -40°C to +80°C
Nominal voltage: U0/U 600/1000 V
A.C. test voltage, 50 Hz: 3000 V
Minimum bending radius: for flexible installation; approx. 5x cable Ø
Properties
PVC self-extinguishing and flame retardant according to DIN VDE 0482 part 265-2-1/ EN 50265-2-1/ IEC 60332-1
(equivalent DIN VDE 0472 part 804 test method B)
Chemical resistance see table Technical Information
Shielded, High flexible PVC single conductor
Conductors x cross-sec. mm² | Outer Diameter | Copper weight kg/km | Weight ca. kg/km | AWG |
1x2.5 | 5.9 | 34.0 | 55.0 | 14 |
1x4 | 6.5 | 50.0 | 75.0 | 12 |
1x6 | 8.3 | 88.0 | 125.0 | 10 |
1x10 | 8.7 | 124.0 | 170.0 | 8 |
1x16 | 10.3 | 190.0 | 300.0 | 6 |
1x25 | 12.4 | 260.0 | 420.0 | 4 |
1x35 | 13.7 | 405.0 | 620.0 | 2 |
1x50 | 15.4 | 560.0 | 825.0 | 1 |
1x70 | 17.5 | 780.0 | 1090.0 | 2/0 |
1x95 | 21.0 | 1030.0 | 1395.0 | 3/0 |
1x120 | 22.4 | 1285.0 | 1770.0 | 4/0 |
1x150 | 24.3 | 1430.0 | 1930.0 | 300 kcmil |
1x185 | 26.5 | 1940.0 | 2635.0 | 350 kcmil |
1x240 | 30.3 | 2530.0 | 3380.0 | 500 kcmil |
1x300 | 35.0 | 2950.0 | 3500.0 | 600 kcmil |