PRODUCTS
- Aerial Bundled Cables
- Airport Cables
- Automotive Cables
- Alarm & Audio & Electronic Cables
- Belden Equivalent Cables
- Bus Cables
- Cable Glands
- Cables for Oil Industry
- Coaxial Cables
- Composite Cables
- Control Cables
- Data Cable
- Elevator Cables
- Fiber Optic Cables
- Fire Resisting Cable(Fireflix)
- Fire Retardant Cable(FIRETOX)
- Flame Retardant Cable (FIREGUARD)
- Flexible Cables
- Heat Detection Cables
- High Temperature Cables
- Highway Cables
- Industrial Cables
- Instrumentation Cables
- Lan Cables
- Marine Cable
- NEK606 Water Blocked Offshore & Marine Cables
- IEC60092 STANDARD Offshore & Marine Cables
- BS 6883&BS7917 STANDARD Offshore & Marine Cables
- UKOOA Offshore & Marine cables
- VG 95218 Navy Cables
- Mining Cables
- Airframe Wire
- Marine, OIL,GAS & Petrochemical Cables
- Power Cables
- Railway Cables
- Robotics
- Rolling Stock Cables
- Rubber & Crane Cables
- Security Cables
- Special Cables
- Spiral Cables
- Telephone Cables
- Thermocouple Cables
- BS 5308 Cable
- PAS 5308 Cable
- BS 5467 Cable
- BS 6724 Cable
- BS 6346 Cable
- BS 7211 Cable
- IEC 60502-1 Cable
HOT PRODUCTS
APPLICATIONS
|
XHHW/CPE, 600V, Type TC Control Cable
Application and Description
XHHW/CPE type TC Control Cable is for use in industrial power or control circuits where small diameter,
flame retardant cables are desired. Primary installations include cable trays, raceways, and outdoor locations
where supported by a messenger wire. Type TC Control Cable is also listed for direct burial and for use in
Class 1, Division 2 hazardous locations and Class 1 control circuits. Constructions with 3 or more conductors
are listed for exposed runs (TC-ER) per NEC 336.10.Conductors may be used in wet or dry locations at
temperatures not to exceed 90°C.
Cable Construction
Conductor: Stranded bare annealed copper, available in size AWG14, 12, 10(Type XHHW-2)
Insulation: Flame-retardant and moisture resistant Cross-Linked Polyethylene (FRXLPE)
Jacket: Flame retardant, moisture and sunlight resistant CPE (PVC/LSOH is available upon request)
Color: upon request, black is preferable
Technical Characteristics
- UL 1277 - Electrical Power and Control Tray Cables
- UL 1685 - UL Flame Exposure Test (70,000 Btu/hr)
- ICEA S-58-679 - Control Cable Conductor Identification Method 1, Table 2
- IEEE 1202 - Flame Testing of Cables for Use in Cable Tray in Industrial and Commercial Occupancies
(70,000 Btu/hr)
Cable Parameter
No.of Cores | Nominal jacket Thickness Inch/mm | Nominal Overall Diameter Inch/mm | Cable Weight Lbs/kft kg/km | |||
AWG 14 (7 strands) | ||||||
2 | 0.045 | 1.14 | 0.349 | 8.86 | 62 | 92 |
3 | 0.045 | 1.14 | 0.370 | 9.40 | 85 | 127 |
4 | 0.045 | 1.14 | 0.403 | 10.24 | 104 | 155 |
5 | 0.045 | 1.14 | 0.440 | 11.18 | 123 | 183 |
7 | 0.045 | 1.14 | 0.479 | 12.17 | 163 | 242 |
9 | 0.060 | 1.52 | 0.588 | 14.94 | 220 | 327 |
12 | 0.060 | 1.52 | 0.659 | 16.74 | 282 | 419 |
15 | 0.060 | 1.52 | 0.730 | 18.54 | 343 | 511 |
19 | 0.060 | 1.52 | 0.768 | 19.51 | 420 | 624 |
25 | 0.080 | 2.03 | 0.938 | 23.83 | 576 | 857 |
37 | 0.080 | 2.03 | 1.067 | 27.10 | 811 | 1206 |
AWG 12 (7 strands) | ||||||
2 | 0.045 | 1.14 | 0.384 | 9.75 | 84 | 125 |
3 | 0.045 | 1.14 | 0.408 | 10.36 | 114 | 169 |
4 | 0.045 | 1.14 | 0.445 | 11.30 | 145 | 216 |
5 | 0.045 | 1.14 | 0.487 | 12.37 | 170 | 252 |
7 | 0.060 | 1.52 | 0.562 | 14.27 | 241 | 358 |
9 | 0.060 | 1.52 | 0.651 | 16.54 | 303 | 452 |
12 | 0.060 | 1.52 | 0.732 | 18.59 | 392 | 583 |
15 | 0.060 | 1.52 | 0.813 | 20.65 | 480 | 714 |
19 | 0.080 | 2.03 | 0.896 | 22.76 | 622 | 925 |
25 | 0.080 | 2.03 | 1.043 | 26.49 | 804 | 1196 |
37 | 0.080 | 2.03 | 1.190 | 30.23 | 1144 | 1702 |
AWG 10 (7 strands) | ||||||
2 | 0.045 | 1.14 | 0.431 | 10.95 | 114 | 170 |
3 | 0.045 | 1.14 | 0.459 | 11.66 | 159 | 236 |
4 | 0.045 | 1.14 | 0.502 | 12.75 | 204 | 303 |
5 | 0.060 | 1.52 | 0.581 | 14.76 | 257 | 382 |
7 | 0.060 | 1.52 | 0.632 | 16.05 | 342 | 510 |
9 | 0.060 | 1.52 | 0.736 | 18.69 | 433 | 645 |
12 | 0.080 | 2.03 | 0.870 | 22.10 | 593 | 883 |
15 | 0.080 | 2.03 | 0.964 | 24.49 | 726 | 1081 |