Home ProuductsIndustrial Cables

American Standard UL Industrial Cables
HALAR/HMWPE Cathodic Protection Power Cable

Application

Theses cables are designed for use in cathodic protection deep well installations or other situations where resistance to chlorine gas is required.The primary ECTFE (Halar) insulation provides chemical resistance properties. The secondary or outter jacket of high molecular weight polyethylene (HMWPE) provides abrasion resistance.

Standard

  • ICEA S-61-402/NEMA WC5

Construction

Conductor Stranded bare copper conductor conforms to ASTM Specification B-3 and B-8.
Insulation A homogeneous wall of natural ECTFE fluoropolymer (Halar) shall be extruded over the conductor.
Jacket Insulation is high molecular weight polyethylene conforming to ASTM-D-1248, Type 1, Class C, Category 5, Grades J1 and E5. Tensile Strengths Jl, J3. Available with high density polyethylene (Types II, III, IV) Class B and C (all colors).

Technical Data

Rated voltage 600V
Operating temperature 75℃

Dimensions

Conductor Size No. of Stranding Circular Mils AWG Diameter HALAR Thickness HMWPE Thickness Nominal Outer Diameter Total weight
    In In In In Lbs/Mft
8 AWG 7 16.51 0.146 0.02 0.065 0.316 83
6 AWG 7 26.24 0.184 0.02 0.065 0.354 120
4 AWG 7 41.74 0.232 0.02 0.065 0.402 177
2 AWG 7 66.36 0.283 0.02 0.065 0.462 260