PRODUCTS
- Aerial Bundled Cables
- Airport Cables
- Automotive Cables
- Alarm & Audio & Electronic Cables
- Belden Equivalent Cables
- Bus Cables
- Cable Glands
- Cables for Oil Industry
- Coaxial Cables
- Composite Cables
- Control Cables
- Data Cables
- Elevator Cables
- Fiber Optic Cables
- Fire Resisting Cable(Fireflix)
- Fire Retardant Cable(FIRETOX)
- Flame Retardant Cable (FIREGUARD)
- Flexible Cables
- Heat Detection Cables
- High Temperature Cables
- Highway Cables
- Industrial Cables
- Instrumentation Cables
- Marine Cable
- NEK606 Water Blocked Offshore & Marine Cables
- IEC60092 STANDARD Offshore & Marine Cables
- BS 6883&BS7917 STANDARD Offshore & Marine Cables
- UKOOA Offshore & Marine cables
- VG 95218 Navy Cables
- Mining Cables
- Airframe Wire
- Marine, OIL,GAS & Petrochemical Cables
- Power Cables
- Railway Cables
- Robotics
- Rolling Stock Cables
- Rubber & Crane Cables
- Security Cables
- Special Cables
- Spiral Cables
- Telephone Cables
- Thermocouple Cables
- BS 5308 Cable
- PAS 5308 Cable
- BS 5467 Cable
- BS 6724 Cable
- BS 6346 Cable
- BS 7211 Cable
- IEC 60502-1 Cable
HOT PRODUCTS
APPLICATIONS
|
XLPE/PVC, Instrumentation, Shielded 600V, UL Type TC,
Individual and Overall Shielded Pairs
Application
These cables are used in free air, raceways or direct burial and in wet or dry locations. What's more, permitted for use in Class I Division 2 industrial hazardous locations per NEC.
Standard:
Industry Standard:
UL 1277 Type TC
UL 1581
ICEA S-82-552
ICEA S-73-532
Flame Tests Standard:
UL 1581 VW-1
UL 1277
IEEE 383
IEEE 1202
CSA FT-4
Other Standard:
EPA 40 CFR, Part 261 for leachable lead content per TCLP
Cable Construction
Conductor: Bare, annealed copper per ASTM B33 class B
Insulation: Flame-retardant Cross-Linked Polyethylene (XLPE).
Color-coded: per ICEA Method 1; Pairs – black and white. One conductor in each pair is
printed alpha-numerically for easy identification.
Shield: Individual pairs are 100% shielded with aluminum/polyester in contact with stranded
tinned copper drain wire.
Overall shield is aluminum/polyester in contact with stranded tinned copper drain wire.
Jacket: Flame-retardant Polyvinyl Chloride (PVC), UV resistance, hydrocarbon resistance,
oil resistance, anti rodent and anti termite properties can be offered as option.
Cable Parameter
NO. of Pairs |
CON. Size (AWG) |
CON. Strand |
Min. AVG. Insulation Thickness |
Min. AVG. Jacket Thickness |
Appr. Cable O.D. |
Appr. Cable Weight |
||||
---|---|---|---|---|---|---|---|---|---|---|
Inches | mm | Inches | mm | Inches | mm | LBS/ 1000 FT |
kg/km | |||
2 | 18 | 7/0.0152 | 0.030 | 0.76 | 0.045 | 1.14 | 0.515 | 13.08 | 95 | 141 |
4 | 18 | 7/0.0152 | 0.030 | 0.76 | 0.060 | 1.52 | 0.625 | 15.88 | 170 | 253 |
8 | 18 | 7/0.0152 | 0.030 | 0.76 | 0.060 | 1.52 | 0.805 | 20.45 | 292 | 435 |
12 | 18 | 7/0.0152 | 0.030 | 0.76 | 0.080 | 2.03 | 1.020 | 25.91 | 442 | 658 |
16 | 18 | 7/0.0152 | 0.030 | 0.76 | 0.080 | 2.03 | 1.130 | 28.70 | 554 | 824 |
20 | 18 | 7/0.0152 | 0.030 | 0.76 | 0.080 | 2.03 | 1.235 | 31.37 | 666 | 991 |
24 | 18 | 7/0.0152 | 0.030 | 0.76 | 0.080 | 2.03 | 1.465 | 37.21 | 802 | 1194 |
36 | 18 | 7/0.0152 | 0.030 | 0.76 | 0.080 | 2.03 | 1.630 | 41.40 | 1116 | 1661 |
50 | 18 | 7/0.0152 | 0.030 | 0.76 | 0.110 | 2.79 | 1.975 | 50.17 | 1598 | 2378 |
2 | 16 | 7/0.0192 | 0.030 | 0.76 | 0.060 | 1.52 | 0.595 | 15.11 | 135 | 201 |
4 | 16 | 7/0.0192 | 0.030 | 0.76 | 0.060 | 1.52 | 0.695 | 17.65 | 214 | 318 |
8 | 16 | 7/0.0192 | 0.030 | 0.76 | 0.060 | 1.52 | 0.900 | 22.86 | 399 | 594 |
12 | 16 | 7/0.0192 | 0.030 | 0.76 | 0.080 | 2.03 | 1.110 | 28.19 | 584 | 869 |
16 | 16 | 7/0.0192 | 0.030 | 0.76 | 0.080 | 2.03 | 1.260 | 32.00 | 712 | 1060 |
20 | 16 | 7/0.0192 | 0.030 | 0.76 | 0.080 | 2.03 | 1.315 | 33.40 | 845 | 1258 |
24 | 16 | 7/0.0192 | 0.030 | 0.76 | 0.080 | 2.03 | 1.510 | 38.35 | 1009 | 1502 |
36 | 16 | 7/0.0192 | 0.030 | 0.76 | 0.110 | 2.79 | 1.820 | 46.23 | 1259 | 1874 |
50 | 16 | 7/0.0192 | 0.030 | 0.76 | 0.110 | 2.79 | 2.095 | 53.21 | 2032 | 3024 |