PRODUCTS
- Aerial Bundled Cables
- Airport Cables
- Automotive Cables
- Alarm & Audio & Electronic Cables
- Belden Equivalent Cables
- Bus Cables
- Cable Glands
- Cables for Oil Industry
- Coaxial Cables
- Composite Cables
- Control Cables
- Data Cables
- Elevator Cables
- Fiber Optic Cables
- Fire Resisting Cable(Fireflix)
- Fire Retardant Cable(FIRETOX)
- Flame Retardant Cable (FIREGUARD)
- Flexible Cables
- Heat Detection Cables
- High Temperature Cables
- Highway Cables
- Industrial Cables
- Instrumentation Cables
- Marine Cable
- NEK606 Water Blocked Offshore & Marine Cables
- IEC60092 STANDARD Offshore & Marine Cables
- BS 6883&BS7917 STANDARD Offshore & Marine Cables
- UKOOA Offshore & Marine cables
- VG 95218 Navy Cables
- Mining Cables
- Airframe Wire
- Marine, OIL,GAS & Petrochemical Cables
- Power Cables
- Railway Cables
- Robotics
- Rolling Stock Cables
- Rubber & Crane Cables
- Security Cables
- Special Cables
- Spiral Cables
- Telephone Cables
- Thermocouple Cables
- BS 5308 Cable
- PAS 5308 Cable
- BS 5467 Cable
- BS 6724 Cable
- BS 6346 Cable
- BS 7211 Cable
- IEC 60502-1 Cable
HOT PRODUCTS
APPLICATIONS
|
EPR/HYP, Medium-Voltage Power, Non-Shielded 2400V, UL
Type MV-90
Application
These cables are used in these applications: pulp and paper mills, petrochemical plants, sewage treatment facilities, water treatment plants, steel mills, textile mills, utility power generating stations, scrubbers and other environmental protections systems, railroad and mining facilities. Also,they are used in industrial and utility applications, where ease of installation is a major concern because of limited space and exposure to personnel is minimal, in wet or dry locations when installed in accordance with NEC, and use in aerial, conduit, open tray and underground duct installations.
Standard:
National Electric Code (NEC)
ICEA S-96-659/NEMA WC71
UL 1072
FAA L824 specification for cable for Underground Airport Lighting Circuits
Listed “oil-resistant II”
Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method
Cable Construction
Conductor: Annealed bare copper Class B strand.
Extruded Strand Shield (ESS): Extruded thermoset semi-conducting stress-control layer
over conductor.
Insulation: Ethylene Propylene Rubber (EPR) insulation, colored to contrast with the black
jacket material.
Jacket: Low-Lead Chlorosulfonated Polyethylene (CSPE)/ Elastomer blend.
Cable Parameter
CON. Size (AWG/ kcmil) |
Nominal CON. Diameter | Nominal Extruded Strand Shield Diameter |
Nominal Insulation Thickness |
Nominal Insulation Diameter | Appr. Cable O.D. | Appr. Cable Weight | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Inches | mm | Inches | mm | Inches | mm | Inches | mm | Inches | mm | LBS/ 1000 FT |
kg/km | |
8 | 0.14 | 3.56 | 0.15 | 3.81 | 0.125 | 3.18 | 0.41 | 10.41 | 0.58 | 14.73 | 196 | 292 |
6 | 0.17 | 4.32 | 0.19 | 4.83 | 0.125 | 3.18 | 0.44 | 11.18 | 0.62 | 15.75 | 241 | 359 |
4 | 0.22 | 5.59 | 0.23 | 5.84 | 0.125 | 3.18 | 0.49 | 12.45 | 0.66 | 16.76 | 308 | 458 |
2 | 0.27 | 6.86 | 0.29 | 7.37 | 0.125 | 3.18 | 0.55 | 13.97 | 0.72 | 18.29 | 408 | 607 |
1 | 0.31 | 7.87 | 0.33 | 8.38 | 0.125 | 3.18 | 0.58 | 14.73 | 0.76 | 19.30 | 476 | 708 |
1/0 | 0.34 | 8.64 | 0.36 | 9.14 | 0.125 | 3.18 | 0.62 | 15.75 | 0.79 | 20.07 | 562 | 836 |
2/0 | 0.38 | 9.65 | 0.41 | 10.41 | 0.125 | 3.18 | 0.66 | 16.76 | 0.84 | 21.34 | 666 | 991 |
3/0 | 0.43 | 10.92 | 0.45 | 11.43 | 0.125 | 3.18 | 0.71 | 18.03 | 0.92 | 23.37 | 823 | 1225 |
4/0 | 0.48 | 12.19 | 0.50 | 12.70 | 0.125 | 3.18 | 0.76 | 19.30 | 0.97 | 24.64 | 983 | 1463 |
250 | 0.53 | 13.46 | 0.55 | 13.97 | 0.140 | 3.56 | 0.84 | 21.34 | 1.08 | 27.43 | 1183 | 1761 |
350 | 0.62 | 15.75 | 0.64 | 16.26 | 0.140 | 3.56 | 0.93 | 23.62 | 1.17 | 29.72 | 1545 | 2299 |
500 | 0.74 | 18.80 | 0.77 | 19.56 | 0.140 | 3.56 | 1.06 | 26.92 | 1.30 | 33.02 | 2077 | 3091 |
750 | 0.91 | 23.11 | 0.94 | 23.88 | 0.155 | 3.94 | 1.26 | 32.00 | 1.54 | 39.12 | 3040 | 4524 |
1000 | 1.06 | 26.92 | 1.09 | 27.69 | 0.155 | 3.94 | 1.42 | 36.07 | 1.70 | 43.18 | 3913 | 5823 |