PRODUCTS
- Aerial Bundled Cables
- Airport Cables
- Automotive Cables
- Alarm & Audio & Electronic Cables
- Belden Equivalent Cables
- Bus Cables
- Cable Glands
- Cables for Oil Industry
- Coaxial Cables
- Composite Cables
- Control Cables
- Data Cables
- Elevator Cables
- Fiber Optic Cables
- Fire Resisting Cable(Fireflix)
- Fire Retardant Cable(FIRETOX)
- Flame Retardant Cable (FIREGUARD)
- Flexible Cables
- Heat Detection Cables
- High Temperature Cables
- Highway Cables
- Industrial Cables
- Instrumentation Cables
- Marine Cable
- NEK606 Water Blocked Offshore & Marine Cables
- IEC60092 STANDARD Offshore & Marine Cables
- BS 6883&BS7917 STANDARD Offshore & Marine Cables
- UKOOA Offshore & Marine cables
- VG 95218 Navy Cables
- Mining Cables
- Airframe Wire
- Marine, OIL,GAS & Petrochemical Cables
- Power Cables
- Railway Cables
- Robotics
- Rolling Stock Cables
- Rubber & Crane Cables
- Security Cables
- Special Cables
- Spiral Cables
- Telephone Cables
- Thermocouple Cables
- BS 5308 Cable
- PAS 5308 Cable
- BS 5467 Cable
- BS 6724 Cable
- BS 6346 Cable
- BS 7211 Cable
- IEC 60502-1 Cable
HOT PRODUCTS
APPLICATIONS
|
TRXLPE/Copper Wire Shield/PVC, Medium-Voltage Power 15KV, UL Type MV-105, 133% Ins. Level, 220 Mils
Application
These cables are suited for use in a broad range of commercial, industrial and utility applications, where reliability is the major concern, space is limited and ease of installation is critical. Besides, they are installed in wet or dry locations accordance with NEC. Also in aerial, direct burial, conduit, open tray and underground duct installations.
Standard:
National Electrical Code (NEC)
ICEA S-93-639/NEMA WC74
ICEA S-97-682
AEIC CS8
UL 1072
Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method
Cable Construction
Conductor: Annealed bare copper, Class B compressed strand in accordance with ASTM
B3, B8.
Extruded Strand Shield (ESS): Extruded thermoset semi-conducting stress-control layer
over conductor.
Insulation: Tree Retardant Cross-Linked Polyethylene (TRXLPE).
Extruded Insulation Shield (EIS): Thermoset semi-conducting polymeric layer free stripping from insulation.
Metallic Shield: A concentric serve of 24 AWG annealed solid bare copper wires over
which shall be applied a lapped non-metallic tape.
Jacket: Flame-retardant Polyvinyl Chloride (PVC), UV resistance, hydrocarbon resistance,
oil resistance, anti rodent and anti termite properties can be offered as option.
Cable Parameter
CON. Size |
Nominal CON. Diameter | Insulation Diameter | Nominal Jacket Thickness |
Appr.Cable O.D. | Appr. Cable Weight |
Ampacity | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inches | mm | Min. | Max. | Inches | mm | Inches | mm | LBS/ 1000 FT | kg/km | In Air | GND. | Tray | |||
(AWG/ kcmil) |
Inches | mm | Inches | mm | |||||||||||
2 | 0.29 | 7.37 | 0.725 | 18.42 | 0.815 | 20.70 | 0.080 | 2.03 | 1.05 | 26.67 | 600 | 893 | 165 | 165 | - |
1 | 0.33 | 8.38 | 0.765 | 19.35 | 0.855 | 21.72 | 0.080 | 2.03 | 1.09 | 27.68 | 671 | 998 | 190 | 185 | - |
1/0 | 0.37 | 9.40 | 0.805 | 20.45 | 0.895 | 22.73 | 0.080 | 2.03 | 1.13 | 28.27 | 761 | 1132 | 215 | 215 | 220 |
2/0 | 0.41 | 10.41 | 0.850 | 21.59 | 0.935 | 23.75 | 0.080 | 2.03 | 1.18 | 29.97 | 871 | 1296 | 255 | 245 | 250 |
4/0 | 0.52 | 13.21 | 0.955 | 24.26 | 1.045 | 26.54 | 0.080 | 2.03 | 1.29 | 32.76 | 1179 | 1754 | 330 | 315 | 335 |
250 | 0.56 | 14.22 | 1.010 | 25.65 | 1.100 | 27.94 | 0.080 | 2.03 | 1.34 | 34.03 | 1327 | 1974 | 365 | 345 | 370 |
350 | 0.67 | 17.02 | 1.115 | 28.32 | 1.200 | 30.48 | 0.080 | 2.03 | 1.45 | 36.83 | 1700 | 2529 | 440 | 415 | 460 |
500 | 0.80 | 20.32 | 1.240 | 31.50 | 1.330 | 33.78 | 0.080 | 2.03 | 1.57 | 39.87 | 2236 | 3327 | 535 | 500 | 575 |
750 | 0.97 | 24.64 | 1.430 | 36.32 | 1.520 | 38.61 | 0.110 | 2.79 | 1.82 | 46.23 | 3225 | 4798 | 655 | 610 | 745 |
1000 | 1.12 | 28.45 | 1.575 | 40.01 | 1.670 | 42.42 | 0.110 | 2.79 | 1.97 | 50.04 | 4090 | 6086 | 755 | 690 | 890 |