Home ProuductsIndustrial Cables

TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded,
Armored 25KV, CSA HVTECK, 100% Ins. Level, 260 Mils,
Three Conductor

Application

These cables are used in ventilated, non-ventilated and ladder type cable trays in dry, damp or wet locations, direct earth burial (with protection as required by inspection authority). They are exposed and concealed wiring in dry, damp or wet locations. Besides,the wires are in all hazardous locations when used with certified HL cable glands.

Standard:

CSA FT1 and FT4
IEEE 383 (70,000 BTU/hr)
UL 1581(70,000 BTU/hr)
IEEE 1202 (70,000 BTU/hr) CSA FT4
ICEA T-30-520 (70,000 BTU/hr)
ICEA T-29-520 (210,000 BTU/hr)
Hazardous location rating: HL
CSA Standard C68.3
CSA Standard C22.2 No. 174
CSA Approval (file) numbers: LR27161
Meets EPA 40 CFR, part 261 for leachable lead content per TCLP method

Cable Construction

Conductor: Bare copper Class B strand.
Strand Shield: A thermoset semi-conducting strand shield is extruded over the conductor.
Insulation: Tree-Retardant Cross-Linked Polyethylene (TR-XLPE).
Insulation Shield: This consists of a semi-conducting thermosetting layer, applied in a triple extrusion process, plus a helically applied gapped copper tape.
Color-Coded: Black, Red or Blue colored tape placed longitudinally under the copper tape shield.
Ground (Bonding) Conductor: The conductor consists of one uninsulated stranded bare copper conductor.
Inner Jacket: Flame-retardant Polyvinyl Chloride (PVC), UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option— Black.
Armor: Aluminum Interlocked Armor (AIA).
Overall Jacket: Flame-retardant Polyvinyl Chloride (PVC), UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option— Black or as requested.

5kv CSA HVTECK

Cable Parameter

NO.
of
CON.
CON.
Size
(AWG)
Ground
Wire Size
AWG
Nominal Diameter (over) Appr. Cable Weight
W/AL Armor
Ampacity
(40°C
Ambient)
Insulation Insulation
Shield
Inner
Jacket
Armor CABLE LBS/
1000
FT
kg/km
Inches mm Inches mm Inches mm Inches mm Inches mm AL Steel AL Steel In Air
3 1 6 0.87 22.10 0.94 23.88 2.26 57.5 2.55 64.8 2.67 67.8 3250 4300 4840 6390 187
3 1/0 6 0.91 23.11 0.97 24.64 2.34 59.5 2.63 66.8 2.74 69.6 3550 4630 5290 6890 215
3 2/0 6 0.95 24.13 1.01 25.65 2.43 61.7 2.72 69.1 2.84 72.2 3930 5040 5850 7500 246
3 3/0 4 0.99 25.15 1.06 26.92 2.54 64.5 2.82 71.6 2.94 74.7 4440 5600 6610 8340 283
3 4/0 4 1.04 26.42 1.13 28.70 2.70 68.5 2.98 75.7 3.10 78.8 5090 6320 7580 9410 325
3 250 4 1.10 27.94 1.18 29.97 2.87 72.9 3.16 80.3 3.29 83.6 5900 7220 8790 10750 359
3 350 3 1.24 31.50 1.33 33.78 3.17 80.5 3.46 87.9 3.60 91.5 7180 8590 10680 12780 438
3 500 3 1.32 33.53 1.41 35.81 3.34 84.9 3.63 92.2 3.76 95.5 8950 10480 13320 15590 536