HomeProuductsControl Cables

IEC 60502 Type Cable0.6/1 kV CVV-S
IEC 60502 (2-15 core)

Application:

For supervisory electrical equipment,station control circuits,outdoor,suitable installation in dry or wet cable treches.
Conductor Concentric Stranded copper wire

Insulation:

PVC Black color
Identification Printed White number on the surface of Black

Insulation:

Filler Suitable filler
Binding tape Suitable tape
Inner sheath PVC Black color
Shield Annealed copper tape
Binding tape Suitable tape
Outher Sheath PVC Black color

2 Core CVV-S Control Cable

Part NO. No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of Insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.) mm Maximum conductor resistance (at 20C) Ohm/km Minimum Insulation resistance (at 70C) Ohm/km Cable weight (Approx.) kg/km Standard Length m
CCL-CT-CVVS-2C0.50SQ 2 0.5 7/0.30 0.8 1.0 1.8 12.5 36.0 0.0162 180 500/D
CCL-CT-CVVS-2C0.75SQ 0.75 7/0.37 0.8 1.0 1.8 13.0 24.5 0.0142 195 500/D
CCL-CT-CVVS-2C1.00SQ 1 7/0.40 0.8 1.0 1.8 13.0 18.1 0.0135 205 500/D
CCL-CT-CVVS-2C1.50Q 1.5 7/0.50 0.8 1.0 1.8 14.0 12.1 0.0115 230 500/D
CCL-CT-CVVS-2C2.50SQ 2.5 7/0.67 0.8 1.0 1.8 15.0 7.41 0.0093 280 500/D
CCL-CT-CVVS-2C4.00SQ 4 7/0.85 1.0 1.0 1.8 17.0 4.61 0.0092 375 500/D
CCL-CT-CVVS-2C6.00SQ 6 7/1.04 1.0 1.0 1.8 18.5 3.08 0.0078 450 500/D

3 Core CVV-S Control Cable

Part NO. No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of Insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.) mm Maximum conductor resistance (at 20C) Ohm/km Minimum Insulation resistance (at 70C) Ohm/km Cable weight (Approx.) kg/km Standard Length m
CCL-CT-CVVS-3C0.50SQ 3 0.5 7/0.30 0.8 1.0 1.8 13.0 36.0 0.0162 195 500/D
CCL-CT-CVVS-3C0.75SQ 0.75 7/0.37 0.8 1.0 1.8 13.5 24.5 0.0142 215 500/D
CCL-CT-CVVS-3C1.00SQ 1 7/0.40 0.8 1.0 1.8 13.5 18.1 0.0135 225 500/D
CCL-CT-CVVS-3C1.50Q 1.5 7/0.50 0.8 1.0 1.8 14.5 12.1 0.0115 260 500/D
CCL-CT-CVVS-3C2.50SQ 2.5 7/0.67 0.8 1.0 1.8 15.5 7.41 0.0093 325 500/D
CCL-CT-CVVS-3C4.00SQ 4 7/0.85 1.0 1.0 1.8 18.0 4.61 0.0092 445 500/D
CCL-CT-CVVS-3C6.00SQ 6 7/1.04 1.0 1.0 1.8 19.0 3.08 0.0078 545 500/D

4 Core CVV-S Control Cable

Part NO. No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of Insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.) mm Maximum conductor resistance (at 20C) Ohm/km Minimum Insulation resistance (at 70C) Ohm/km Cable weight (Approx.) kg/km Standard Length m
CCL-CT-CVVS-4C0.50SQ 4 0.5 7/0.30 0.8 1.0 1.8 13.5 36.0 0.0162 220 500/D
CCL-CT-CVVS-4C0.75SQ 0.75 7/0.37 0.8 1.0 1.8 14.0 24.5 0.0142 245 500/D
CCL-CT-CVVS-4C1.00SQ 1 7/0.40 0.8 1.0 1.8 14.5 18.1 0.0135 260 500/D
CCL-CT-CVVS-4C1.50Q 1.5 7/0.50 0.8 1.0 1.8 15.5 12.1 0.0115 300 500/D
CCL-CT-CVVS-4C2.50SQ 2.5 7/0.67 0.8 1.0 1.8 16.5 7.41 0.0093 385 500/D
CCL-CT-CVVS-4C4.00SQ 4 7/0.85 1.0 1.0 1.8 19.0 4.61 0.0092 530 500/D
CCL-CT-CVVS-4C6.00SQ 6 7/1.04 1.0 1.0 1.8 20.5 3.08 0.0078 660 500/D

5 Core CVV-S Control Cable

Part NO. No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of Insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.) mm Maximum conductor resistance (at 20C) Ohm/km Minimum Insulation resistance (at 70C) Ohm/km Cable weight (Approx.) kg/km Standard Length m
CCL-CT-CVVS-5C0.50SQ 5 0.5 7/0.30 0.8 1.0 1.8 14.5 36.0 0.0162 250 500/D
CCL-CT-CVVS-5C0.75SQ 0.75 7/0.37 0.8 1.0 1.8 15.0 24.5 0.0142 280 500/D
CCL-CT-CVVS-5C1.00SQ 1 7/0.40 0.8 1.0 1.8 15.5 18.1 0.0135 295 500/D
CCL-CT-CVVS-5C1.50Q 1.5 7/0.50 0.8 1.0 1.8 16.5 12.1 0.0115 345 500/D
CCL-CT-CVVS-5C2.50SQ 2.5 7/0.67 0.8 1.0 1.8 18.0 7.41 0.0093 445 500/D
CCL-CT-CVVS-5C4.00SQ 4 7/0.85 1.0 1.0 1.8 20.5 4.61 0.0092 620 500/D
CCL-CT-CVVS-5C6.00SQ 6 7/1.04 1.0 1.0 1.8 22.5 3.08 0.0078 780 500/D

6 Core CVV-S Control Cable

Part NO. No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of Insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.) mm Maximum conductor resistance (at 20C) Ohm/km Minimum Insulation resistance (at 70C) Ohm/km Cable weight (Approx.) kg/km Standard Length m
CCL-CT-CVVS-6C0.50SQ 6 0.5 7/0.30 0.8 1.0 1.8 15.5 36.0 0.0162 270 500/D
CCL-CT-CVVS-6C0.75SQ 0.75 7/0.37 0.8 1.0 1.8 16.0 24.5 0.0142 305 500/D
CCL-CT-CVVS-6C1.00SQ 1 7/0.40 0.8 1.0 1.8 16.5 18.1 0.0135 320 500/D
CCL-CT-CVVS-6C1.50Q 1.5 7/0.50 0.8 1.0 1.8 17.5 12.1 0.0115 375 500/D
CCL-CT-CVVS-6C2.50SQ 2.5 7/0.67 0.8 1.0 1.8 19.0 7.41 0.0093 290 500/D
CCL-CT-CVVS-6C4.00SQ 4 7/0.85 1.0 1.0 1.8 22.0 4.61 0.0092 685 500/D
CCL-CT-CVVS-6C6.00SQ 6 7/1.04 1.0 1.0 1.8 24.0 3.08 0.0078 865 500/D

7 Core CVV-S Control Cable

Part NO. No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of Insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.) mm Maximum conductor resistance (at 20C) Ohm/km Minimum Insulation resistance (at 70C) Ohm/km Cable weight (Approx.) kg/km Standard Length m
CCL-CT-CVVS-7C0.50SQ 7 0.5 7/0.30 0.8 1.0 1.8 15.5 36.0 0.0162 275 500/D
CCL-CT-CVVS-7C0.75SQ 0.75 7/0.37 0.8 1.0 1.8 16.0 24.5 0.0142 315 500/D
CCL-CT-CVVS-7C1.00SQ 1 7/0.40 0.8 1.0 1.8 16.5 18.1 0.0135 330 500/D
CCL-CT-CVVS-7C1.50Q 1.5 7/0.50 0.8 1.0 1.8 17.5 12.1 0.0115 395 500/D
CCL-CT-CVVS-7C2.50SQ 2.5 7/0.67 0.8 1.0 1.8 19.0 7.41 0.0093 520 500/D
CCL-CT-CVVS-7C4.00SQ 4 7/0.85 1.0 1.0 1.8 22.0 4.61 0.0092 730 500/D
CCL-CT-CVVS-7C6.00SQ 6 7/1.04 1.0 1.0 1.8 24.0 3.08 0.0078 930 500/D

8 Core CVV-S Control Cable

Part NO. No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of Insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.) mm Maximum conductor resistance (at 20C) Ohm/km Minimum Insulation resistance (at 70C) Ohm/km Cable weight (Approx.) kg/km Standard Length m
CCL-CT-CVVS-8C0.50SQ 8 0.5 7/0.30 0.8 1.0 1.8 16.0 36.0 0.0162 310 500/D
CCL-CT-CVVS-8C0.75SQ 0.75 7/0.37 0.8 1.0 1.8 17.0 24.5 0.0142 350 500/D
CCL-CT-CVVS-8C1.00SQ 1 7/0.40 0.8 1.0 1.8 17.0 18.1 0.0135 370 500/D
CCL-CT-CVVS-8C1.50Q 1.5 7/0.50 0.8 1.0 1.8 18.5 12.1 0.0115 445 500/D
CCL-CT-CVVS-8C2.50SQ 2.5 7/0.67 0.8 1.0 1.8 20.0 7.41 0.0093 590 500/D
CCL-CT-CVVS-8C4.00SQ 4 7/0.85 1.0 1.0 1.8 23.5 4.61 0.0092 835 500/D
CCL-CT-CVVS-8C6.00SQ 6 7/1.04 1.0 1.0 1.8 25.5 3.08 0.0078 1070 500/D

9 Core CVV-S Control Cable

Part NO. No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of Insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.) mm Maximum conductor resistance (at 20C) Ohm/km Minimum Insulation resistance (at 70C) Ohm/km Cable weight (Approx.) kg/km Standard Length m
CCL-CT-CVVS-9C0.50SQ 9 0.5 7/0.30 0.8 1.0 1.8 17.0 36.0 0.0162 340 500/D
CCL-CT-CVVS-9C0.75SQ 0.75 7/0.37 0.8 1.0 1.8 18.0 24.5 0.0142 390 500/D
CCL-CT-CVVS-9C1.00SQ 1 7/0.40 0.8 1.0 1.8 18.0 18.1 0.0135 415 500/D
CCL-CT-CVVS-9C1.50Q 1.5 7/0.50 0.8 1.0 1.8 19.5 12.1 0.0115 495 500/D
CCL-CT-CVVS-9C2.50SQ 2.5 7/0.67 0.8 1.0 1.8 21.5 7.41 0.0093 660 500/D
CCL-CT-CVVS-9C4.00SQ 4 7/0.85 1.0 1.0 1.8 25.0 4.61 0.0092 945 500/D
CCL-CT-CVVS-9C6.00SQ 6 7/1.04 1.0 1.0 1.8 27.5 3.08 0.0078 1215 500/D

10 Core CVV-S Control Cable

Part NO. No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of Insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.) mm Maximum conductor resistance (at 20C) Ohm/km Minimum Insulation resistance (at 70C) Ohm/km Cable weight (Approx.) kg/km Standard Length m
CCL-CT-CVVS-10C0.50SQ

10

0.5 7/0.30 0.8 1.0 1.8 18.0 36.0 0.0162 370 500/D
CCL-CT-CVVS-10C0.75SQ 0.75 7/0.37 0.8 1.0 1.8 19.0 24.5 0.0142 425 500/D
CCL-CT-CVVS-10C1.00SQ 1 7/0.40 0.8 1.0 1.8 19.5 18.1 0.0135 445 500/D
CCL-CT-CVVS-10C1.50Q 1.5 7/0.50 0.8 1.0 1.8 20.5 12.1 0.0115 540 500/D
CCL-CT-CVVS-10C2.50SQ 2.5 7/0.67 0.8 1.0 1.8 23.0 7.41 0.0093 720 500/D
CCL-CT-CVVS-10C4.00SQ 4 7/0.85 1.0 1.0 1.8 27.0 4.61 0.0092 1030 500/D
CCL-CT-CVVS-10C6.00SQ 6 7/1.04 1.0 1.0 1.8 29.5 3.08 0.0078 1325 500/D

11 Core CVV-S Control Cable

Part NO. No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of Insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.) mm Maximum conductor resistance (at 20C) Ohm/km Minimum Insulation resistance (at 70C) Ohm/km Cable weight (Approx.) kg/km Standard Length m
CCL-CT-CVVS-11C0.50SQ 11 0.5 7/0.30 0.8 1.0 1.8 18.5 36.0 0.0162 395 500/D
CCL-CT-CVVS-11C0.75SQ 0.75 7/0.37 0.8 1.0 1.8 19.5 24.5 0.0142 455 500/D
CCL-CT-CVVS-11C1.00SQ 1 7/0.40 0.8 1.0 1.8 20.0 18.1 0.0135 480 500/D
CCL-CT-CVVS-11C1.50Q 1.5 7/0.50 0.8 1.0 1.8 21.0 12.1 0.0115 580 500/D
CCL-CT-CVVS-11C2.50SQ 2.5 7/0.67 0.8 1.0 1.8 23.5 7.41 0.0093 780 500/D
CCL-CT-CVVS-11C4.00SQ 4 7/0.85 1.0 1.0 1.8 28.0 4.61 0.0092 1125 500/D
CCL-CT-CVVS-11C6.00SQ 6 7/1.04 1.0 1.0 1.8 30.5 3.08 0.0078 1450 500/D

12 Core CVV-S Control Cable

Part NO. No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of Insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.) mm Maximum conductor resistance (at 20C) Ohm/km Minimum Insulation resistance (at 70C) Ohm/km Cable weight (Approx.) kg/km Standard Length m
CCL-CT-CVVS-12C0.50SQ 12 0.5 7/0.30 0.8 1.0 1.8 18.5 36.0 0.0162 400 500/D
CCL-CT-CVVS-12C0.75SQ 0.75 7/0.37 0.8 1.0 1.8 19.5 24.5 0.0142 460 500/D
CCL-CT-CVVS-12C1.00SQ 1 7/0.40 0.8 1.0 1.8 20.0 18.1 0.0135 490 500/D
CCL-CT-CVVS-12C1.50Q 1.5 7/0.50 0.8 1.0 1.8 21.0 12.1 0.0115 595 500/D
CCL-CT-CVVS-12C2.50SQ 2.5 7/0.67 0.8 1.0 1.8 23.5 7.41 0.0093 805 500/D
CCL-CT-CVVS-12C4.00SQ 4 7/0.85 1.0 1.0 1.8 28.0 4.61 0.0092 1160 500/D
CCL-CT-CVVS-12C6.00SQ 6 7/1.04 1.0 1.0 1.8 30.5 3.08 0.0078 1500 500/D

13 Core CVV-S Control Cable

Part NO.

No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of Insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.) mm Maximum conductor resistance (at 20C) Ohm/km Minimum Insulation resistance (at 70C) Ohm/km Cable weight (Approx.) kg/km Standard Length m

CCL-CT-CVVS-13C0.50SQ

13

0.5 7/0.30 0.8 1.0 1.8 19.0 36.0 0.0162 435 500/D

CCL-CT-CVVS-13C0.75SQ

0.75 7/0.37 0.8 1.0 1.8 20.0 24.5 0.0142 505 500/D

CCL-CT-CVVS-13C1.00SQ

1 7/0.40 0.8 1.0 1.8 20.5 18.1 0.0135 530 500/D

CCL-CT-CVVS-13C1.50Q

1.5 7/0.50 0.8 1.0 1.8 22.0 12.1 0.0115 645 500/D

CCL-CT-CVVS-13C2.50SQ

2.5 7/0.67 0.8 1.0 1.8 24.5 7.41 0.0093 875 500/D

CCL-CT-CVVS-13C4.00SQ

4 7/0.85 1.0 1.0 1.8 29.0 4.61 0.0092 1275 500/D

CCL-CT-CVVS-13C6.00SQ

6 7/1.04 1.0 1.0 1.9 32.0 3.08 0.0078 1665 500/D

14 Core CVV-S Control Cable

Part NO.

No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of Insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.) mm Maximum conductor resistance (at 20C) Ohm/km Minimum Insulation resistance (at 70C) Ohm/km Cable weight (Approx.) kg/km Standard Length m
CCL-CT-CVVS-14C0.50SQ

14

0.5 7/0.30 0.8 1.0 1.8 19.0 36.0 0.0162 435 500/D
CCL-CT-CVVS-14C0.75SQ 0.75 7/0.37 0.8 1.0 1.8 20.0 24.5 0.0142 505 500/D
CCL-CT-CVVS-14C1.00SQ 1 7/0.40 0.8 1.0 1.8 20.5 18.1 0.0135 540 500/D
CCL-CT-CVVS-14C1.50Q 1.5 7/0.50 0.8 1.0 1.8 22.0 12.1 0.0115 660 500/D
CCL-CT-CVVS-14C2.50SQ 2.5 7/0.67 0.8 1.0 1.8 24.5 7.41 0.0093 900 500/D
CCL-CT-CVVS-14C4.00SQ 4 7/0.85 1.0 1.0 1.8 29.0 4.61 0.0092 1305 500/D
CCL-CT-CVVS-14C6.00SQ 6 7/1.04 1.0 1.0 1.9 32.0 3.08 0.0078 1715 500/D

15 Core CVV-S Control Cable

Part NO.

No.of core Nominal cross-sectional area sq.mm No.&dia.of wires No./mm Thickness of Insulation mm Thickness of inner sheath mm Thickness of outer sheath mm Overall diameter (Approx.) mm Maximum conductor resistance (at 20C) Ohm/km Minimum Insulation resistance (at 70C) Ohm/km Cable weight (Approx.) kg/km Standard Length m
CCL-CT-CVVS-15C0.50SQ

15

0.5 7/0.30 0.8 1.0 1.8 20.0 36.0 0.0162 475 500/D
CCL-CT-CVVS-15C0.75SQ 0.75 7/0.37 0.8 1.0 1.8 21.0 24.5 0.0142 550 500/D
CCL-CT-CVVS-15C1.00SQ 1 7/0.40 0.8 1.0 1.8 21.5 18.1 0.0135 585 500/D
CCL-CT-CVVS-15C1.50Q 1.5 7/0.50 0.8 1.0 1.8 23.0 12.1 0.0115 715 500/D
CCL-CT-CVVS-15C2.50SQ 2.5 7/0.67 0.8 1.0 1.8 25.5 7.41 0.0093 980 500/D
CCL-CT-CVVS-15C4.00SQ 4 7/0.85 1.0 1.0 1.8 30.5 4.61 0.0092 1425 500/D
CCL-CT-CVVS-15C6.00SQ 6 7/1.04 1.0 1.0 1.9 34.0 3.08 0.0078 1875 500/D