URM Coax

URM 70 LSF

Product Name/Code : URM70 LSF Electrical Performance
Application : Max.Conductor DC Resistance at 20 ℃(Ω /Km ) 9 3.800 93.8
For communication and signal control systems. Min.Insulation DC Resistance at 20 ℃( M Ω *Km ) >500
Reference Standard Operating Temperature( ℃ ) 70
Customer's sample spec. and the general standard Voltage Rating(V) 30
Cable Construction Capacitance(pF/m) 67+/-5
Number of Cores 1 Velocity ratio (%) 66.7+/-5
Conductor Bare Copper Impedance( Ω ) 75+/-3
Construction 0.19/7 Attenuation at 20 ℃ (-dB/100m)
100MHz 13.8
Conductor Diameter(mm) 0.58 300MHz 25.5
Insulation Solid PE 500MHz 33.0
Min. Thickness(mm) 1.310 700MHz 41.5
Insulation Diameter (±0.03mm) 3.20 900MHz 47.8
Screening(mm) Bare Copper Braid 1000MHz 50.1
Construction 16 / 6/0.12    
Braid Coverage(%) 81    
Sheathing LSF    
Min. Thickness(mm) 1.18    
Diameter(±0.10mm) 5.80    
Sheathing Compound PVC/LSF/LSOH    
Core Identification/Color Code According to customer request    
Bending Radius 6xOverall Diameter    
Temperature Rating 70℃    
Voltage Rating 300/500V    
Fire Performance      
Flame Propagation Test to IEC 60332 Part 1 ( PVC /LSOH) Flame Propagation Test to IEC 60332 Part 1 and Part 3 ( FRPVC/LSFROH ) Determination of the amount Halogen Acid Gas to IEC 60754 Part 1 ( LSOH ) Smoke Density Test to IEC 61034 ( LSOH ) Oxygen Index Test to BS 2863 or ISO 4589-2 ( LSOH ) Temperature Index Test to BS 2782 or ISO 4589-3 ( LSOH )    
Website: www.caledonian-cables.net    
E-mail: sales@caledonian-cables.com