PRODUCTS
- Aerial Bundled Cables
- Airport Cables
- Automotive Cables
- Alarm & Audio & Electronic Cables
- Belden Equivalent Cables
- Bus Cables
- Cable Glands
- Cables for Oil Industry
- Coaxial Cables
- Composite Cables
- Control Cables
- Data Cable
- Elevator Cables
- Fiber Optic Cables
- Fire Resisting Cable(Fireflix)
- Fire Retardant Cable(FIRETOX)
- Flame Retardant Cable (FIREGUARD)
- Flexible Cables
- Heat Detection Cables
- High Temperature Cables
- Highway Cables
- Industrial Cables
- Instrumentation Cables
- Lan Cables
- Marine Cable
- NEK606 Water Blocked Offshore & Marine Cables
- IEC60092 STANDARD Offshore & Marine Cables
- BS 6883&BS7917 STANDARD Offshore & Marine Cables
- UKOOA Offshore & Marine cables
- VG 95218 Navy Cables
- Mining Cables
- Airframe Wire
- Marine, OIL,GAS & Petrochemical Cables
- Power Cables
- Railway Cables
- Robotics
- Rolling Stock Cables
- Rubber & Crane Cables
- Security Cables
- Special Cables
- Spiral Cables
- Telephone Cables
- Thermocouple Cables
- BS 5308 Cable
- PAS 5308 Cable
- BS 5467 Cable
- BS 6724 Cable
- BS 6346 Cable
- BS 7211 Cable
- IEC 60502-1 Cable
HOT PRODUCTS
APPLICATIONS
|
Solid PE Insulated & PE Sheathed Jelly Filled Cables to CW 1326& CW 1326/1179
Application
The CW 1326& CW 1326/1179 telephone cables are designed for use as subscriber distribution cables and as connection between central offices in local access networks. The cables are jelly filled and suitable for installation in ducts. The cables are also available for direct burial in the ground and aerial installation with integral suspension strand. An armoured option is offered for direct burial installations. A figure-8 self support option is offered for aerial installation.
Standards
• CW 1326 (For unscreened cable)
• CW 1179 (For screened cable)
• CW 1252 (For self-supporting cable)
Construction
Conductors:
Solid annealed bare copper, 0.5mm as per class 1 of BS 6360/IEC 60228
Insulation:
Solid polyethylene as per BS EN 50290-2-23/BS 6234/IEC 60708
TwistedPairs:
Insulated conductors are twisted into pairs with varying lay length to minimize crosstalk
CablingElement:
Twisted Pairs
CableCore Assembly:
Cables are composed of 10-pair units
Core Wrapping:
One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap. These tapes furnish thermal, mechanical as well as high dielectric protection between shielding and individual conductors
Moisture Barrier (optional):
A layer of aluminium tape (0.15mm) coated with PE-copolymer on one or both sides is applied longitudinally with overlap over the cable core to provide shielding coverage and ensure a barrier against water vapor
Filling:
The cable core interstices are filled with petroleum jelly to avoid longitudinal water penetration within the cable. The water resistant filling compound is applied to the air space between non-hygroscopic tape and shield, shield and sheath within the cable core
Sheath:
Black low density polyethylene as per BS 6234/IEC 60708, being able to withstand exposure to sunlight, temperature variations, ground chemicals and other environmental contaminants
Ripcord:
Ripcord may be provided for slitting the sheath longitudinally to facilitate its removal
SparePairs (optional):
Spare pairs may be incorporated for 200 and larger pair cables
Continuity Wire (optional):
Tinned copper drain wire may be longitudinally laid to ensure electrical continuity of the screen
Electrical Properties
Nominal Conductor Diameter | mm | 0.5 |
---|---|---|
Conductor Gauge Size | AWG | 24 |
Conductor Size | mm2 | 0.196 |
Maximum Average Conductor Resistance @20°C | Ω/km | 91 |
Minimum Insulation Resistance @500V DC | MΩ.km | 1500 |
Maximum Average Mutual Capacitance @800Hz* | nF/km | 56 |
Maximum Individual Mutual Capacitance @800Hz (for 99% cases) | nF/km | 64 |
Maximum Individual Capacitance Unbalance @800Hz pair-to-pair | pF/500m | 275 |
Maximum Conductor Loop Resistance @20°C | Ω/km | 192 |
Impedance @1KHz | Ω | 796 |
Impedance @100KHz | Ω | 134 |
Impedance @512KHz | Ω | 118 |
Impedance @1MHz | Ω | 115 |
Maximum Average Attenuation @0.8KHz | dB/km | 1.30 |
Maximum Average Attenuation @1KHz | dB/km | 1.35 |
Maximum Average Attenuation @3KHz | dB/km | 2.52 |
Maximum Average Attenuation @150KHz | dB/km | 8.3 |
Maximum Average Attenuation @772KHz | dB/km | 19.4 |
Maximum Average Attenuation @1000KHz | dB/km | 21.4 |
Dielectric Strength Conductor to Conductor (3secs) | V DC | 500 |
Nominal Insulation Thickness | mm | 0.275 |
Nominal Insulated Conductor Diameter | mm | 1.05 |
*For screened cables of 20 pairs or less, the maximum average mutual capacitance shall not apply and the maximum for 99% of cases shall be increased by 3nF
Mechanical and Thermal Properties
Temperature range during operation (fixed state): -30°C – +70°C
Temperaturerange during installation (mobile state): -20°C – +50°C
Minimumbending radius: 10 x Overall Diameter (unarmoured cables);15 x Overall Diameter (armoured cables)
Colour Code
Standard colour code is per CW 1326 given in the following Colour Code ChartCabling Element No. | a-wire | b-wire | Cabling Element No. | a-wire | b-wire |
---|---|---|---|---|---|
1 | WHITE | BLUE | 6 | RED | BLUE |
2 | WHITE | ORANGE | 7 | RED | ORANGE |
3 | WHITE | GREEN | 8 | RED | GREEN |
4 | WHITE | BROWN | 9 | RED | BROWN |
5 | WHITE | GREY | 10 | RED | GREY |
Units binders
No. of Units | Binder Colour | No. of Units | Binder Colour |
---|---|---|---|
1 | BLUE | 6 | WHITE |
2 | ORANGE | 7 | RED |
3 | GREEN | 8 | BLACK |
4 | BROWN | 9 | YELLOW |
5 | GREY | 10 | VIOLET |
Dimensions And Weight
Solid PE Insulated and Unscreened/Screened PE Sheathed Jelly Filled Cable to CW 1326, CW 1326/1179
Cable Code | Number of Pairs | Minimum Sheath Thickness mm |
Maximum Overall Diameter mm (Unscreened) |
Nominal Weight kg/km (Unscreened) |
Maximum Overall Diameter mm (Screened) | Nominal Weight kg/km (Screened) |
---|---|---|---|---|---|---|
0.5mm Conductor, 1.05mm Insulated Wire | ||||||
TP1326-2YF(L)2Y-2P05 | 2 | 1.1 | 8.5 | 55 | 10.0 | 65 |
TP1326-2YF(L)2Y-5P05 | 5 | 1.2 | 8.5 | 77 | 10.0 | 87 |
TP1326-2YF(L)2Y-10P05 | 10 | 1.2 | 12.0 | 126 | 13.5 | 137 |
TP1326-2YF(L)2Y-20P05 | 20 | 1.3 | 15.0 | 221 | 16.5 | 231 |
TP1326-2YF(L)2Y-30P05 | 30 | 1.4 | 18.0 | 332 | 19.5 | 347 |
TP1326-2YF(L)2Y-50P05 | 50 | 1.4 | 19.5 | 483 | 21.0 | 504 |
TP1326-2YF(L)2Y-100P05 | 100 | 1.5 | 25.0 | 933 | 26.5 | 956 |
Solid PE Insulated, PE Inner Sheathed, Steel Wire Armoured and PE Outer Sheathed Jelly Filled Cable to CW 1326/1198 (Unscreened)
Cable Code | Number of Pairs |
Minimum Bedding Thickness mm |
Steel Wire Diameter mm |
Minimum Sheath Thickness mm |
Maximum Overall Diameter mm |
Nominal Weight kg/km |
---|---|---|---|---|---|---|
0.5mm Conductor, 1.05mm Insulated Wire | ||||||
TP1326-2YF2Y(SWA)2Y-2P05 | 2 | 1.1 | 0.9 | 0.9 | 13.7 | 241 |
TP1326-2YF2Y(SWA)2Y-5P05 | 5 | 1.2 | 0.9 | 0.9 | 13.7 | 274 |
TP1326-2YF2Y(SWA)2Y-10P05 | 10 | 1.2 | 0.9 | 0.9 | 17.2 | 351 |
TP1326-2YF2Y(SWA)2Y-20P05 | 20 | 1.3 | 1.25 | 0.9 | 20.9 | 499 |
TP1326-2YF2Y(SWA)2Y-30P05 | 30 | 1.4 | 2.0 | 1.0 | 24.8 | 749 |
TP1326-2YF2Y(SWA)2Y-50P05 | 50 | 1.4 | 2.0 | 1.0 | 26.3 | 1123 |
TP1326-2YF2Y(SWA)2Y-100P05 | 100 | 1.5 | 2.0 | 1.1 | 32.0 | 1763 |
Solid PE Insulated, PE Inner Sheathed, Steel Wire Armoured and PE Outer Sheathed Jelly Filled Cable to CW 1326
/1179/1198 (Screened)
Cable Code | Number of Pairs |
Minimum Bedding Thickness mm |
Steel Wire Diameter mm |
Minimum Sheath Thickness mm |
Maximum Overall Diameter mm |
Nominal Weight kg/km |
---|---|---|---|---|---|---|
0.5mm Conductor, 1.05mm Insulated Wire | ||||||
TP1326-2YF(L)2Y(SWA)2Y-2P05 | 2 | 1.1 | 0.9 | 0.9 | 15.2 | 251 |
TP1326-2YF(L)2Y(SWA)2Y-5P05 | 5 | 1.2 | 0.9 | 0.9 | 15.2 | 286 |
TP1326-2YF(L)2Y(SWA)2Y-10P05 | 10 | 1.2 | 1.25 | 0.9 | 19.4 | 363 |
TP1326-2YF(L)2Y(SWA)2Y-20P05 | 20 | 1.3 | 2.0 | 1.0 | 23.3 | 501 |
TP1326-2YF(L)2Y(SWA)2Y-30P05 | 30 | 1.4 | 2.0 | 1.0 | 26.3 | 752 |
TP1326-2YF(L)2Y(SWA)2Y-50P05 | 50 | 1.4 | 2.0 | 1.1 | 28.0 | 1139 |
TP1326-2YF(L)2Y(SWA)2Y-100P05 | 100 | 1.5 | 2.0 | 1.2 | 30.5 | 1786 |