HomeProuductsRolling Stock Cables

EN 50306 Thin Wall Instrumentation & Control Cable
FIREROL FRL-TW-05M-SW

EN 50306 Thin Wall Rolling Stock Cables FRL-TW-05M-SW

A. Conductor B. Insulation C. Sheath

Application

-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor.

-Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.

Construction

Conductor
Tinned annealed copper wires as defined in EN 50306-2

Insulation
LSZH special compound

Outer sheath
LSZH special compound (S2. EM101- EM104)

Electrical & Mechanical Properties

Nominal Voltage 300/500 V
Maximum Conductor Temperature +120/+150 deg (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 deg (fixed installation)
Bending Radius 3 x Overall Diameter (D<12mm);
4 x Overall Diameter (D>12mm)

Chemical & Environmental Properties

EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application

EN 50306-2 Hazard levels HL1, HL2, HL3
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 F0
EN45545-2
R15 Interior/ R16 Exterior HL1, HL2, HL3

Fire Performance in general

EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index
EN45545-2 Requirement for fire behavior of materials & components R15/R16

FRL-TW-05M-SW 300/500 V

NUMBER OF CORES AND NOMINAL CROSS SECTION MINIMUM THICKNESS OF SHEATH AT ANY POINT OVERALL DIAMETER WEIGHT
(mm2) (mm) min. (mm) max. (mm) (kg/km)
4 x 0.5 0.42 4.1 5.1 30
7 x 0.5 0.42 4.9 5.9 50
13 x 0.5 0.56 7.3 8.3 100
19 x 0.5 0.56 8.1 9.1 140
37 x 0.5 0.56 10.8 12.0 250
4 x 0.75 0.42 4.6 5.6 40
7 x 0.75 0.42 5.5 6.5 70
13 x 0.75 0.56 8.2 9.2 130
19 x 0.75 0.56 9.0 10.2 180
37 x 0.75 0.56 12.2 13.4 340
48 x 0.75 0.56 13.9 15.5 440
4 x 1.0 0.42 4.9 5.9 50
7 x 1.0 0.42 6.0 7.0 90
13 x 1.0 0.56 8.7 9.9 160
19 x 1.0 0.56 9.8 11.0 230
37 x 1.0 0.56 13.3 14.5 430
4 x 1.5 0.42 6.0 7.0 80
7 x 1.5 0.56 7.7 9.8 140
13 x 1.5 0.56 10.7 11.9 250
19 x 1.5 0.56 12.0 13.2 350
37 x 1.5 0.56 16.2 17.8 650
         
2 x 2.5 0.56 6.7 7.7 70
3 x 2.5 0.56 7.7 8.1 110
4 x 2.5 0.56 7.9 8.9 140