HomeProuductsRolling Stock Cables

EN 50306 Thin Wall Instrumentation & Control Rolling Stock Cable
FIREROL FRL-TW-05MP-SW-OS

EN 50306 Thin Wall rolling stock cable FIREROL FRL-TW-05MP-SW-OS

A.Conductor B.Insulation C.Screen D.Sheath

Application

-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor.

-Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.

Construction

Conductor
Tinned annealed copper wires as defined in EN 50306-2

Insulation
LSZH special compound

Pair Identification
Pairs numbered according to EN 50306-4

Overall screen
Tinned annealed copper wires

Outer sheath
LSZH special compound (S2. EM 101 - EM 104)

Electrical & Mechanical Properties

Nominal Voltage 300/500 V
Maximum Conductor Temperature +90/+105 deg (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 deg (fixed installation)
Bending Radius 10 x Overall Diameter

Chemical & Environmental Properties

EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application

EN 50306-2 Hazard levels HL1, HL2, HL3
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 F0
EN45545-2
R15 Interior/ R16 Exterior HL1, HL2, HL3

Fire Performance in general

EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index
EN45545-2 Requirement for fire behavior of materials & components R15/R16

FRL-TW-05MP-SW-OS 300/500 V

NUMBER OF CORES AND NOMINAL CROSS SECTION MINIMUM THICKNESS OF SHEATH AT ANY POINT OVERALL DIAMETER WEIGHT
(mm2) (mm) min. (mm) max. (mm) (kg/km)
2 x 2 x 0.5 0.56 6.6 7.9 61
3 x 2 x 0.5 0.56 7.0 8.1 78
4 x 2 x 0.5 0.56 7.7 8.7 96
7 x 2 x 0.5 0.56 9.0 10.6 146
 
2 x 2 x 0.75 0.56 7.1 9.0 80
3 x 2 x 0.75 0.56 7.7 9.2 103
4 x 2 x 0.75 0.56 9.0 10.0 128
7 x 2 x 0.75 0.56 10.8 11.8 200
 
2 x 2 x 1.0 0.56 7.8 9.5 95
3 x 2 x 1.0 0.56 8.3 9.7 125
4 x 2 x 1.0 0.56 9.1 10.3 156
7 x 2 x 1.0 0.56 11.0 12.4 247
 
2 x 2 x 1.5 0.56 9.8 11.2 126
3 x 2 x 1.5 0.56 10.4 11.4 168
4 x 2 x 1.5 0.56 11.6 12.6 212
7 x 2 x 1.5 0.56 14.0 15.3 340