HomeProuductsRolling Stock Cables

RS 485 Databus Cables 300/500 V
FRL-MVB-02Y(ST)CH-IOS-xPyS/FRL-MVB-02YCH-OS-xPyS

EN 50382 High Temperature Rolling Stock Cable FRL-HT-6SURI

A. Conductor B. Insulation+Pair Screen C. Overall Screen D. Sheath

Application

120 Ohm data transmission cables

Construction

Multipair Databus RS 485 Double Screened Cable

Conductor: Stranded tin plated copper conductor according to IEC 60228 class 5(0.22mm2-1mm2).
Insulation: Cross linked foam PE or foam skin PE
Cable Element: Twisted pair
Pair Screen:Individual Aluminium tape
Overall Screen: Copper wire braid
Outer Sheath: Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1

Multipair Databus RS 485 Single Screened Cable

Conductor: Stranded tin plated copper conductor according to IEC 60228 class 5(0.22mm2-1mm2)
Insulation: Cross linked foam PE or foam skin PE
Cable Element: Twisted pair
Overall Screen: Copper wire braid
Outer Sheath: Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1

Electrical & Mechanical Properties

Nominal Voltage 300/500 V
Impedance 120 Ω+/-15 %
Capacitance@1KHz 41 nF/km
Min. Insulation Resistance 5000 MΩ

Chemical & Environmental Properties

EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to mineral oil & fuel oil, acid & alkali
EN 50305 Resistance to ozone

Fire Performance for Rolling Stock Application

EN 50306-2 Hazard levels HL1, HL2, HL3
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 F0
EN45545-2
R15 Interior/ R16 Exterior HL1, HL2, HL3

Fire Performance in general

EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) Vertical flame propagation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804 Vertical flame spread of vertically mounted bunched wires or cables
EN 50268-2; IEC 61034-2; NF C 32-073 ;NF C 20-902; NF F 16 101; VDE 0472 Teil 816 Low Smoke Emission
EN 50267-2-1; IEC 60754-1; NF C 32-074; NF C 20-454; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; NF C 32-074;NF C 20-453; VDE 0472 Teil 813 Low Corrosivity (Acidity & Conductivity)
EN 50305; NF X 70-100; NF F 63 808; TM1-04; BS6853 Low Toxicity
NF F 63 808; BS6853; NF F 16 101 Smoke index
EN45545-2 Requirement for fire behavior of materials & components R15/R16

FRL-MVB-02Y(ST)CH-IOS-xPyS 300/500 V

No.of Pairs Cross Sectional Area mm2

Number and Nominal Diameter of Strands

mm

Nominal Overall
Diameter

mm

Nominal Weight kg/km
1 0.22 7/0.2 4.5 58
2 0.22 7/0.2 6.2 79
4 0.22 7/0.2 6.5 118
1 0.5 16/0.2 6.6 79
2 0.5 16/0.2 9.0 105
4 0.5 16/0.2 9.8 145
1 0.75 24/0.2 9.5 115
2 0.75 24/0.2 10.3 135
4 0.75 24/0.2 11.6 182
1 1 30/0.2 11.5 125
2 1 30/0.2 12.5 150
4 1 30/0.2 13.5 180

FRL-MVB-02YCH-OS-xPyS 300/500 V

No. of Pairs Cross Sectional Area mm2

Number and Nominal Diameter of Strands

mm

Nominal Overall
Diameter

mm

Nominal Weight kg/km
1 0.22 7/0.2 4.2 55
2 0.22 7/0.2 5.9 75
4 0.22 7/0.2 6.2 115
1 0.5 16/0.2 6.3 75
2 0.5 16/0.2 8.5 100
4 0.5 16/0.2 9.4 140
1 0.75 24/0.2 9.0 110
2 0.75 24/0.2 9.7 130
4 0.75 24/0.2 11.1 178
1 1 30/0.2 11.0 120
2 1 30/0.2 12.0 145
4 1 30/0.2 13.0 175