HomeProuductsRailway Cables

 TYPE E3 Railway Signalling Cable

TYPE E3 Railway Signalling Cable

Application

The  TYPE E3 Railway Signalling Cable are designed for railway signalling systems. The cables are suitable for use in d.c. circuits where the nominal voltage to earth does not exceed 1100 volts and installation in ducts.

Standards

● NR/PS/SIG/00005(formerly RT/E/PS/00005)

Construction

Conductors
Tinned stranded copper, according to IEC 60228 class 5& BS 6360.

Insulation
LSZH or EPR Type GP4 to BS 7655.

Screen
Aluminium tape.

Drain Wire
2.5 mm² fl exible tinned copper.

Sheath
LSZH.

Electrical Characteristics at 20℃

Nominal Conductor Cross Section mm² 2.5
Maximum DC Conductor Resistance Ω/km 8.21
Minimum Noise Reduction dB 60
Voltage Rating KV 0.65/1.1
Nominal Insulation Thickness mm 1.05

Mechanical and Thermal Properties

Minimum Bending Radius: 6×OD (static); 15×OD (dynamic)
Temperature Range: -25℃ to +85℃ (during operation); -10℃ to +85℃ (during installation)

Dimensions And Weight

Cable Code No. of cores& Nominal
Conductor Cross
Sectional Area
No.×mm²
No. & Nominal
Diameter of
Strands
No/mm
Nominal
Sheath
Thickness
mm
Overall
Diameter
Min/Max
mm
Nominal
Weight
kg/km
Type E3
RS/E3-3G(St)H-1P2.5S 1 x 2 x 2.5 50/0.25 3.8 15.0/20.0 410

Routine test voltage: 2.5kV for 5 minutes