HomeProuductsRailway Cables

CCTSST-FR0.3 n×4×1.4 Railway Cables

CCTSST-FR0.3 n×4×1.4 Railway Cables

Application

The CCTSST-FR0.3 n×4×1.4 Railway Cables are used as railway cables and can be installed directly into the ground or in ducts.

Standards

RENFE E.T. 03.365.051.6

Construction

Conductors
Soft annealed solid copper, 1.4 mm nominal diameter.

Insulation
PE insulation.

Cabling Element
Four insulated conductors are twisted together to form a quad.

Stranding
Quads are helically stranded in concentric layers.

Core Wrapping
Two or more layers of plastic tape(s) with overlapping.

Screen
Copper tapes with overlap (protection against interference).

Inner Sheath
LSZH sheath, coloured green.

Armour
Two layers steel tape (0.8mm thick).

Outer Sheath
LSZH sheath, coloured green.

Electrical Characteristics at 20℃

Nominal Conductor Diameter mm 1.4
Maximum Conductor Resistance Ω/km 11.7
Minimum Insulation Resistance @500 V DC MΩ.km 35000
Mutual Capacitance @800Hz nF/km 45
Capacitance Unbalance @800Hz
K1 maximum individual value pF/460m 250
K9-12 maximum individual value pF/460m 250
ea1/2 maximum individual value pF/460m 1200
Test Voltage @50Hz 1min
Core to Core Veff 2100
Core to Screen Veff 2500
Reduction Factor @100V/km 50Hz 0.3

Mechanical and Thermal Properties

Minimum Bending Radius: 10×OD
Temperature Range: -40℃ to +60℃ (during operation); -10℃ to +60℃ (during installation)

Dimensions And Weight

Cable Code Number of
Quads
Nominal Sheath Thickness
mm
Maximum Overall
Diameter
mm
Nominal Weight
kg/km
Inner Outer
1.4mm Conductor, 2.6mm Insulated Wire
RS/CCTSST-FR0.3-2Y(K)HBH-1Q1.4 1 1.5 1.6 19.0 880
RS/CCTSST-FR0.3-2Y(K)HBH-3Q1.4 3 1.5 1.6 27.1 1440
RS/CCTSST-FR0.3-2Y(K)HBH-5Q1.4 5 1.5 1.6 31.0 1826
RS/CCTSST-FR0.3-2Y(K)HBH-7Q1.4 7 1.5 1.6 33.1 2090
RS/CCTSST-FR0.3-2Y(K)HBH-10Q1.4 10 1.7 1.8 38.4 2640
RS/CCTSST-FR0.3-2Y(K)HBH-14Q1.4 14 1.7 1.8 42.2 3168
RS/CCTSST-FR0.3-2Y(K)HBH-19Q1.4 19 1.8 2.0 47.2 3861