Application

The CCPSSP-FR0.3 n×2×0.9/1.4 Railway Cables are used as railway cables and can be installed directly into the ground or in ducts.

Standards

RENFE E.T. 03.365.051.6

Construction

Conductors
Soft annealed solid copper, 0.9 mm nominal diameter.

Insulation
PE insulation.

Cabling Element
Four insulated conductors are twisted together to form a quad.

Stranding
Quads are helically stranded in concentric layers.

Core Wrapping
At least one layer of water swellable material with overlapping.

Inner Sheath
PE sheath.

Screen
1.4/1.8mm copper wires wrapping with one plastic tape (protection against interference).

Intermediate Sheath
PE sheath.

Armour
Two layers of steel tape (0.8mm thick).

Outer Sheath
PE sheath.

Electrical Characteristics at 20℃

Nominal Conductor Diameter mm 0.9
Maximum Conductor Resistance Ω/km 28.5
Minimum Insulation Resistance @500 V DC MΩ.km 25000
Mutual Capacitance @800Hz nF/km 41
Capacitance Unbalance @800Hz
K1 maximum individual value pF/460m 250
K9-12 maximum individual value pF/460m 250
ea1/2 maximum individual value pF/460m 1200
Attenuation
@1KHz dB/km 0.7
@10KHz dB/km 1.6
@30KHz dB/km 2.1
Test Voltage @50Hz 1min
Core to Core Veff 2100
Core to Screen Veff 2500
Core to Armouring Veff 2000
Reduction Factor @100V/km 50Hz 0.1

Mechanical and Thermal Properties

Minimum Bending Radius: 10×OD
Temperature Range: -30℃ to +70℃ (during operation); -5℃ to +50℃ (during installation)

Dimensions And Weight

Cable Code Number of
Quads
Nominal Sheath Thickness
mm
Maximum Overall
Diameter
mm
Nominal Weight
kg/km
Inner Inter. Outer
0.9mm Conductor, 1.8mm Insulated Wire
RS/CCPSSP-R-FR0.1-2Y(F)2YD2YB2Y-1Q0.9 1 1.5 1.5 1.6 23.7 1300
RS/CCPSSP-R-FR0.1-2Y(F)2YD2YB2Y-3Q0.9 3 1.5 1.5 1.6 27.7 1648
RS/CCPSSP-R-FR0.1-2Y(F)2YD2YB2Y-5Q0.9 5 1.5 1.5 1.6 31.5 1984
RS/CCPSSP-R-FR0.1-2Y(F)2YD2YB2Y-25Q0.9 25 1.7 1.7 1.8 51.3 4166