PRODUCTS
- Aerial Bundled Cables
- Airport Cables
- Automotive Cables
- Alarm & Audio & Electronic Cables
- Belden Equivalent Cables
- Bus Cables
- Cable Glands
- Cables for Oil Industry
- Coaxial Cables
- Composite Cables
- Control Cables
- Data Cable
- Elevator Cables
- Fiber Optic Cables
- Fire Resisting Cable(Fireflix)
- Fire Retardant Cable(FIRETOX)
- Flame Retardant Cable (FIREGUARD)
- Flexible Cables
- Heat Detection Cables
- High Temperature Cables
- Highway Cables
- Industrial Cables
- Instrumentation Cables
- Lan Cables
- Marine Cable
- NEK606 Water Blocked Offshore & Marine Cables
- IEC60092 STANDARD Offshore & Marine Cables
- BS 6883&BS7917 STANDARD Offshore & Marine Cables
- UKOOA Offshore & Marine cables
- VG 95218 Navy Cables
- Mining Cables
- Airframe Wire
- Marine, OIL,GAS & Petrochemical Cables
- Power Cables
- Railway Cables
- Robotics
- Rolling Stock Cables
- Rubber & Crane Cables
- Security Cables
- Special Cables
- Spiral Cables
- Telephone Cables
- Thermocouple Cables
- BS 5308 Cable
- PAS 5308 Cable
- BS 5467 Cable
- BS 6724 Cable
- BS 6346 Cable
- BS 7211 Cable
- IEC 60502-1 Cable
HOT PRODUCTS
APPLICATIONS
|
CCPSSP-R-FR0.1 Railway Cables
Application
The CCPSSP-FR0.3 n×2×0.9/1.4 Railway Cables are used as railway cables and can be installed directly into the ground or in ducts.
Standards
RENFE E.T. 03.365.051.6
Construction
Conductors
Soft annealed solid copper, 0.9 mm nominal diameter.
Insulation
PE insulation.
Cabling Element
Four insulated conductors are twisted together to form a quad.
Stranding
Quads are helically stranded in concentric layers.
Core Wrapping
At least one layer of water swellable material with overlapping.
Inner Sheath
PE sheath.
Screen
1.4/1.8mm copper wires wrapping with one plastic tape (protection against interference).
Intermediate Sheath
PE sheath.
Armour
Two layers of steel tape (0.8mm thick).
Outer Sheath
PE sheath.
Electrical Characteristics at 20℃
Nominal Conductor Diameter | mm | 0.9 |
---|---|---|
Maximum Conductor Resistance | Ω/km | 28.5 |
Minimum Insulation Resistance @500 V DC | MΩ.km | 25000 |
Mutual Capacitance @800Hz | nF/km | 41 |
Capacitance Unbalance @800Hz | ||
K1 maximum individual value | pF/460m | 250 |
K9-12 maximum individual value | pF/460m | 250 |
ea1/2 maximum individual value | pF/460m | 1200 |
Attenuation | ||
@1KHz | dB/km | 0.7 |
@10KHz | dB/km | 1.6 |
@30KHz | dB/km | 2.1 |
Test Voltage @50Hz 1min | ||
Core to Core | Veff | 2100 |
Core to Screen | Veff | 2500 |
Core to Armouring | Veff | 2000 |
Reduction Factor @100V/km 50Hz | 0.1 |
Mechanical and Thermal Properties
Minimum Bending Radius: 10×OD
Temperature Range: -30℃ to +70℃ (during operation); -5℃ to +50℃ (during installation)
Dimensions And Weight
Cable Code | Number of Quads |
Nominal Sheath Thickness mm |
Maximum Overall Diameter mm |
Nominal Weight kg/km |
||
---|---|---|---|---|---|---|
Inner | Inter. | Outer | ||||
0.9mm Conductor, 1.8mm Insulated Wire | ||||||
RS/CCPSSP-R-FR0.1-2Y(F)2YD2YB2Y-1Q0.9 | 1 | 1.5 | 1.5 | 1.6 | 23.7 | 1300 |
RS/CCPSSP-R-FR0.1-2Y(F)2YD2YB2Y-3Q0.9 | 3 | 1.5 | 1.5 | 1.6 | 27.7 | 1648 |
RS/CCPSSP-R-FR0.1-2Y(F)2YD2YB2Y-5Q0.9 | 5 | 1.5 | 1.5 | 1.6 | 31.5 | 1984 |
RS/CCPSSP-R-FR0.1-2Y(F)2YD2YB2Y-25Q0.9 | 25 | 1.7 | 1.7 | 1.8 | 51.3 | 4166 |