PRODUCTS
- Aerial Bundled Cables
- Airport Cables
- Automotive Cables
- Alarm & Audio & Electronic Cables
- Belden Equivalent Cables
- Bus Cables
- Cable Glands
- Cables for Oil Industry
- Coaxial Cables
- Composite Cables
- Control Cables
- Data Cable
- Elevator Cables
- Fiber Optic Cables
- Fire Resisting Cable(Fireflix)
- Fire Retardant Cable(FIRETOX)
- Flame Retardant Cable (FIREGUARD)
- Flexible Cables
- Heat Detection Cables
- High Temperature Cables
- Highway Cables
- Industrial Cables
- Instrumentation Cables
- Lan Cables
- Marine Cable
- NEK606 Water Blocked Offshore & Marine Cables
- IEC60092 STANDARD Offshore & Marine Cables
- BS 6883&BS7917 STANDARD Offshore & Marine Cables
- UKOOA Offshore & Marine cables
- VG 95218 Navy Cables
- Mining Cables
- Airframe Wire
- Marine, OIL,GAS & Petrochemical Cables
- Power Cables
- Railway Cables
- Robotics
- Rolling Stock Cables
- Rubber & Crane Cables
- Security Cables
- Special Cables
- Spiral Cables
- Telephone Cables
- Thermocouple Cables
- BS 5308 Cable
- PAS 5308 Cable
- BS 5467 Cable
- BS 6724 Cable
- BS 6346 Cable
- BS 7211 Cable
- IEC 60502-1 Cable
HOT PRODUCTS
APPLICATIONS
|
Category 5E Data Cables
Application
The Category 5E Data Cables are designed for permanently protected installation, inside and outside railway rolling stock, buses and other vehicles to connect fixed parts. Ethernet based networks as: infotainment, multimedia, passenger information system etc.
Standards
● DIN 5510-2
● EN 50228-2-2
● BS 6853
● EN 50306-3 par 4.8/4.9/4.10
Construction
For 4×0.5mm², 4×22AWG cables:
Conductors
Stranded tin platedcopper conductor (for 0.5mm² cables) or stranded silver plated copper conductor (for 22AWG cables) according to IEC 60228 class 5.
Insulation
Electron beam crosslinkable compound.
Cable Element
Individual conductor stranded together.
EMC Screen1
Plastic laminated aluminium-tape.
EMC Screen2
Tinned copper braid.
Separator (s)
Plastic tape.
Outer Sheath
Electron beam crosslinkable compound.
For 4×2×22AWG cables:
Center
PE fi ller.
4 pairs 2×22AWG
Stranded tinned copper conductor according to IEC 60228 class 5.
Insulation
Electron beam crosslinkable compound.
EMC Screen1
Plastic laminated aluminium-tape.
EMC Screen2
Tinned copper braid.
Separator(s)
Plastic tape.
Outer Sheath
Electron beam crosslinkable compound.
Electrical Characteristics at 20℃
Nominal Cross Section | mm² | 0.5 | - |
---|---|---|---|
AWG | - | 22 | |
Nominal Conductor Resistance | Ω/km | 40.1 | 54.4 |
Maximum Resistance Unbalance | Ω/km | 1.1 | 1.1 |
Maximum Capacitance | |||
Core to Core | pF/m | 65 | 65 |
Core to Screen | pF/m | 100 | 100 |
Characteristic Impedance @100MHz | Ω | 100+/-5 | 100+/-5 |
Transfer Impedance f≤30MHz | mΩ/m V | 200 | 200 |
Nominal Voltage Rating | 300 | 300 |
Mechanical and Thermal Properties
Minimum Bending Radius:6×OD
Temperature Range:-40℃ to +90℃
Dimensions And Weight
Cable Code | No. of cores& Nominal Conductor Cross Sectional Area No.×mm² |
Nominal Diameter of Strands No/mm |
Nominal Sheath Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
---|---|---|---|---|---|
RD-Cat5E-4C0.5S | 4×0.5 | 19/0.18 | 1.2 | 8.3 | 102 |
RD-Cat5E-4C22A | 4×22AWG | 19/0.16 | 1.2 | 7.25 | 81 |
RD-Cat5E-4P22A | 4×2×22AWG | 19/0.16 | 1.2 | 12.6 | 174 |