HomeProuductsRailway Cables

0.45/0.75KV Multicore Thin Wall Traction Cables

Application

Multicore power and control cable designed for protected, fi xed installation inside and outside railway vehicles for connecting fi xed and moving parts.

Standards

● BS 6853 -1a
● DIN 5510-1 1-4
● NFF 16-101 F0

Construction

Conductors
Circular Class 5 stranded plain or tinned copper to BS EN 60228: 2005 / BS 6360

Insulation
Electronbeam crosslinkable thin wall LSZH compound

Outer Sheath
Electron beam crosslinkable LSZH compound

Optional

FRA-TW-0.75M-OS (Screened)
FRA-TW-0.75M-FR (Fire resistant)

Electrical Characteristics at 20℃

Nominal Conductor Cross Section AWG 20 18 16 14 12 10
Maximum Conductor Resistance Ω/km 28.3 17.9 14.1 8.3 6.8 3.6
Voltage Rating KV 0.45/0.75

Mechanical and Thermal Properties

Minimum Bending Radius:3×OD (OD<12mm); 4×OD (OD>12mm)
Temperature Range:-40℃ to +120℃

Dimensions And Weight

Cable Code No. of cores& Nominal
Conductor Cross
Sectional Area
No. x AWG
Nominal Diameter
of Strands
No/mm
Nominal Insulation
Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km

FRA-TW-0.75M-2C20A 2×20 19/0.2 0.18 4.2 32
FRA-TW-0.75M-2C18A 2×18 19/0.25 0.18 4.6 39
FRA-TW-0.75M-2C16A 2×16 19/0.3 0.18 5.3 54
FRA-TW-0.75M-2C14A 2×14 37/0.25 0.22 6.1 66
FRA-TW-0.75M-2C12A 2×12 37/0.3 0.28 7.3 92
FRA-TW-0.75M-3C20A 3×20 19/0.2 0.18 4.4 46
FRA-TW-0.75M-3C18A 3×18 19/0.25 0.18 4.95 62
FRA-TW-0.75M-4C20A 4×20 19/0.2 0.18 4.65 59
FRA-TW-0.75M-4C18A 4×18 19/0.25 0.18 5.2 80
FRA-TW-0.75M-4C16A 4×16 19/0.3 0.18 6.0 104