NSSHCGEOEU 0.6/1kV Coal Cutter Cable (Low Tensile Stress)
Applications
These cables are used for the connection of mobile machines under extremely high mechanical loads, predominantly in mining situations, e.g. for coal-cutting machines, suitable for extreme bending loads under low tensile stress.
Standards
DIN VDE 0250 Part 812
Construction
Conductors |
Flexible stranded tinned copper conductor. |
Insulation |
Heat resistant 3GI3 rubber based on EPR. |
Outer Conductor Layer |
Easy strippable outer conductive layer. |
Pilot Cores |
Copper strand and steel braid conductor capable of expansion and compression with EPR rubber insulation. |
Monitoring Cores |
Spiral of tinned copper wires above the pilot cores, covered with a semiconductive tape. |
Inner Sheath |
Rubber type GM1b. |
Armour/Earth Conductor |
Concentric earth conductor as spiral of copper and steel wires, fibreglas tape, embedded in the outer sheath which prevents sheath exchanging. |
Outer Sheath |
Rubber type 5GM5, abrasion and tear resistant, oil resistant and flame retardant. |
Dimensions and Weight
Number of Cores×Nominal Cross Section |
Minimum Overall Diameter |
Maximum Overall Diameter |
Nominal Weight |
No. ×mm^2 |
mm |
mm |
kg/km |
3×16/16KON+2ST+UEL |
35.0 |
38.0 |
2130 |
3×25/16KON+2ST+UEL |
38.0 |
41.0 |
2790 |
3×35/16KON+2ST+UEL |
41.0 |
45.0 |
3390 |
3×50/25KON+2ST+UEL |
47.0 |
51.0 |
4340 |
3×70/35KON+2ST+UEL |
52.0 |
56.0 |
5680 |
3×95/50KON+2ST+UEL |
58.0 |
62.0 |
7180 |
3×25/16KON+3×(1.5ST+UEL) |
38.0 |
41.0 |
2920 |
3×35/16KON+3×(1.5ST+UEL) |
41.0 |
45.0 |
3630 |
3×50/25KON+3×(1.5ST+UEL) |
45.0 |
48.0 |
4500 |
3×70/35KON+3×(1.5ST+UEL) |
48.0 |
53.0 |
5850 |
3×95/50KON+3×(1.5ST+UEL) |
52.0 |
56.0 |
7400 |
3×120/70KON+3×(1.5ST+UEL) |
58.0 |
63.0 |
8300 |
3×150/70KON+3×(1.5ST+UEL) |
62.0 |
68.0 |
9300 |