HomeProuductsCoaxial Cables

RF12(1/2″) Coaxial Cables

Constructioncs

Inner conductor  Corrugated copper tube  Φ4.83 mm 
Dielectric  Foam PE  Φ12.95 mm 
Outer conductor  Corrugated copper  Φ13.97 mm 
Sheath  PE/LSOH  Φ15.88 mm 

Electrical & Mechanical Characteristics

Impedance  50±3 Ohm 
Nominal capacitance  76 pF/m 
Velocity of propagation  88%
Insulation resistance  >5000 Mohm.Km 
Inner conductor resistance  1.48 Ohm/Km 
Outer conductor resistance  1.90 Ohm/Km 
Installation temperature range  -40°C - +60 °C 
Operating temperature range  -55°C - +85°C 
Test voltage  4 KV 
Cable weight (approx.)  220kg/km 
Operating Frequency Band  1 – 8800 MHz 
Screening effectiveness  >120dB 

Attenuation

Frequency   Attenuation   Attenuation   Frequency   Attenuation   Attenuation  
(MHz) (dB/100m) (dB/100ft) (MHz) (dB/100m) (dB/100ft)
10 0.67 0.2 1800 10.06 3.07
100 2.17 0.66 2000 10.67 3.25
150 2.67 0.81 2100 10.96 3.34
200 3.1 0.95 2200 11.25 3.43
300 3.84 1.17 2300 11.54 3.52
450 4.75 1.45 2500 12.09 3.69
500 5.02 1.53 2700 12.63 3.85
700 6.01 1.83 3000 13.41 4.09
800 6.46 1.97 4000 15.82 4.82
900 6.86 2.09 5000 18.01 5.49
1000 7.28 2.22 6000 20.06 6.12
1500 9.09 2.77 8000 23.82 7.26
1700 9.74 2.97 8800 25.24 7.7

Return Loss

806-960 MHz  24.3dB
1700-2000 MHz  24.3dB