Construction

Inner conductor  Silver plated copper  7 x 0.80 mm 
Dielectric  Solid PTFE  Φ7.25 ± 0.10 mm 
Outer conductor (shield 1)  Silver plated copper (0.16mm)  Φ7.95 ± 0.10 mm 
Inner sheath  FEP  Φ9.00 ± 0.10 mm 
Outer conductor (shield 2)  Silver plated copper (0.2mm)  Φ9.90 ± 0.10 mm 
Outer sheath  FEP  Φ11.10 ± 0.10 mm 

Electrical & Mechanical Characteristics

Impedance  50±3 Ohm
Nominal capacitance  94 pF/m 
Velocity of propagation  70%
Insulation resistance  - Mohm.Km
Inner conductor resistance  - Ohm/Km 
Outer conductor resistance  - Ohm/Km 
Operatig Voltage(max)  4.4 KV 
Test Voltage 
Operating temperature range  -55°C - +200 °C 
Cable weight (approx.)  290 Kg/Km 
Screening effectiveness  >60 dB 

Attenuation

Frequency (MHz)   Attenuation (dB/100 m)   Max. Attenuation(dB/100ft)  
100 7 2.1
200 10 3
400 14 4.3
900 22 6.7
1200 25 7.6
1500 29 8.8
1800 32 9.8
2000 34 10.4
2500 39 11.9