HomeProuductsCoaxial Cables

M17/6-RG 11 (RG11A/U) Coaxial Cables

Construction

Inner conductor  Tinned copper  7 x 0.40 mm 
Dielectric  Low density PE  Φ7.25 ± 0.18 mm 
Outer conductor (shield)  Plain copper  192 x 0.18 mm 
Shield coverage  97%
Sheath  PVC or LSZH  Φ10.3 ± 0.18 mm 

Electrical & Mechanical Characteristics

Impedance  75±5 Ohm 
Nominal capacitance  67 pF/m 
Velocity of propagation  66%
Insulation resistance  >2000 Mohm.Km 
Inner conductor resistance  20.5 Ohm/Km 
Outer conductor resistance  4.5 Ohm/Km 
Test/Operatig Voltage(max)  8.0 KV/5.0 KV 
Operating temperature range  -30 °C - +70 °C 
Copper weight  57 Kg/Km 
Cable weight (approx.)  145.2 Kg/Km 
Screening effectiveness  >55 dB 

Attenuation

Frequency(MHz)  Attenuation (dB/100 m)   Attenuation (dB/100ft) 
50 4.2 1.28
100 6.2 1.89
200 9.3 2.84
400 13.8 4.21
500 15.5 4.73
600 17.1 5.21
860 20.1 6.13
1000 23.4 7.13

Return Loss

30-300 MHz  >30dB
300-600 MHz  >27dB
600-900 MHz  >25dB