HomeProuductsCoaxial Cables

CK175/H2F10:RG175AF + 2 x 0.75mm2+ 10 x 0.5mm2 Coaxial Cables

Construction

Inner conductor 1  Copper covered steel(CCS)  9 x 0.10 mm 
Dielectric  Low density PE  Φ1.50 ± 0.08 mm 
Outer conductor (shield)  Tinned copper  72 x 0.10 mm 
Shield coverage  90%
Sheath  PVC  Φ2.80 ± 0.13 mm 
Inner conductor 2  Plain copper  2x 0.75 mm2 
Insulated cores 2  PVC  2 x Φ1.70 ± 0.10 mm 
Inner conductor 3  Plain copper  10 x 0.5 mm2 
Insulated cores 3  PVC  10 x Φ1.50 ± 0.10 mm 
Overall sheath  Φ9.90 ± 0.30 mm 

Electrical & Mechanical Characteristics

Impedance  75±5 Ohm 
Nominal capacitance  67 pF/m 
Velocity of propagation  66%
Insulation resistance  >2000 Mohm.Km 
Inner conductor resistance  250 Ohm/Km 
Outer conductor resistance  35 Ohm/Km 
Operating temperature range  -25°C - +80 °C 
Cores resistance 0.50 mm2/0.75 mm2  39Ohm/Km/26 Ohm/Km 
Operatig Voltage(max)  0.25 KV/0.3 KV 
Test Voltage  1.2 KV/2.0 KV 
Copper weight  64.45 Kg/Km 
Cable weight (approx.)  172.65 Kg/Km 
fectiveness  >50 dB 

Attenuation

Frequency(MHz)   Attenuation (dB/100 m)   Attenuation (dB/100 ft)  
50 19.2 5.85
100 27.9 8.51
200 40.7 12.41
400 59.2 18.05
500 67.5 20.58
600 72.6 22.13
860 91.1 27.77
1000 101 30.79

Return Loss

30-300 MHz  >20dB
300-600 MHz  >20dB
600-900 MHz  >20dB