Construction

Inner conductor1  Plain copper  9 x 0.10 mm 
Dielectric  Low density PE  Φ1.50 ± 0.08 mm 
Outer conductor  Tinned copper  72 x 0.10 mm 
Shield coverage  90%
Sheath  PVC  Φ2.80 ± 0.13 mm 
Inner conductor 2  Plain copper  3 x 0.22 mm2 
Insulated cores 2  PVC(Green +Yellow + Red)  3 x Φ1.00 ± 0.10 mm 
Overall sheath  Φ5.30 ± 0.20 mm 

Electrical & Mechanical Characteristics

Impedance  75±5 Ohm 
Nominal capacitance  67 pF/m 
Velocity of propagation  66%
Insulation resistance  >2000 Mohm.Km 
Inner conductor resistance  250 Ohm/Km 
Outer conductor resistance  35 Ohm/Km 
Operating temperature range  -25°C - +80 °C 
Cores resistance  82 Ohm/Km 
Test/Operatig Voltage(max)  1.2 KV/0.25 KV 
Copper weight  11.85 Kg/Km 
Cable weight (approx.)  43.2 Kg/Km 
Screening effectiveness  >50 dB 

Attenuation

Frequency(MHz)   Attenuation (dB/100 m)  Attenuation (dB/100 ft)  
50 19.2 5.85
100 27.9 8.51
200 40.7 12.41
400 59.2 18.05
500 67.5 20.58
600 72.6 22.13
860 91.1 27.77
1000 101 30.79

Return Loss

30-300 MHz  >20dB
300-600 MHz  >20dB
600-900 MHz  >20dB