Coaxial Cables  
RG Coax URM Coax CT Coax

CT Coax

CCL-VATC-02

Product Name/Code : CCL-VATC-02

Electrical Performance

Application :

Electrical Characteristics:

For communication and signal control systems. Frequency Attenuation

Reference Standard

(MHz) (dB/100m)
Customer's sample spec. and the general standard 47 4.30
100 6.00

Cable Construction

230 8.90

Center Conductor

Bare Copper

300 10.20
Dia.(mm) 1/1.13 400 11.80

Insulation

Solid PE

800 17.50
Nom. Thickness(mm) 1.8 860 17.90
Insulation Dia. (±0.03mm) 4.8 1000 19.50

Bonded Al/Polyester Foil

1350 23.00
Coverage Area(%) >=100  1750  26.3
Tinned Copper Braid Shield

2050 28.9
Construction 16/ 6/0.12 2150 29.5
Coverage Area(%) >=60 2400 31.3

Jacket

PVC

Nom. Thickness(mm) 0.9 Operating Temperature( ℃ ) 60
Cable Dia.(±0.10mm) 6.8 Capacitance(pF/m) 52

Jacket Compound

PVC/LSF/LSOH

 Impedance(+/-3 Ω ) 75
Core Identification/Color Code According to customer request Velocity ratio (+/-5%) 83
Bending Radius 6 x Overall Diameter

Temperature Rating 70 ℃

Voltage Rating 300/500V

Fire Performance

Flame Propagation Test to IEC 60332 Part 1 ( PVC /LSOH) Flame Propagation Test to IEC 60332 Part 1 and Part 3 ( FRPVC/LSFROH ) Determination of the amount Halogen Acid Gas to IEC 60754 Part 1 ( LSOH ) Smoke Density Test to IEC 61034 ( LSOH ) Oxygen Index Test to BS 2863 or ISO 4589-2 ( LSOH ) Temperature Index Test to BS 2782 or ISO 4589-3 ( LSOH )