Coaxial Cables  
RG Coax URM Coax CT Coax

RG Coax

RG11
Product Name/Code : RG11 Electrical Performance
Application : Electrical Characteristics:
For communication and signal control systems. Frequency Attenuation
Reference Standard (MHz) (dB/100m)
Customer's sample spec. and the general standard 50 3.3
100 5.0
Cable Construction 200 7.0
Center Conductor Bare Copper/CCS 400 9.0
Dia. 1/1.63 700 13.0
Insulation Foam Skin PE 900 14.6
Nom. Thickness(mm) 2.81 1000 18.5
Insulation Dia. (±0.03mm) 7.25 Operating Temperature( ) 60
Bare Copper Braid Shield Capacitance(pF/m) 56
Construction 16/ 7/0.12 Velocity ratio (+/-5%) 78
Coverage Area(%) >=95  Impedance(+/-3 Ω )  75
Jacket PVC
Nom. Thickness(mm) 1.07
Cable Dia.(±0.10mm) 10.3
Jacket Compound PVC/LSF/LSOH
Core Identification/Color Code According to customer request
Bending Radius 6 x Overall Diameter
Temperature Rating 70 ℃
Voltage Rating 300/500V
Fire Performance
Flame Propagation Test to IEC 60332 Part 1 ( PVC /LSOH) Flame Propagation Test to IEC 60332 Part 1 and Part 3 ( FRPVC/LSFROH ) Determination of the amount Halogen Acid Gas to IEC 60754 Part 1 ( LSOH ) Smoke Density Test to IEC 61034 ( LSOH ) Oxygen Index Test to BS 2863 or ISO 4589-2 ( LSOH ) Temperature Index Test to BS 2782 or ISO 4589-3 ( LSOH )